Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
273
User Manual 1173.9240.02 ─ 23
Specific commands:
[SENSe:]ADEMod<n>:SPECtrum:SPAN:ZOOM
................................................................273
[SENSe:]ADEMod<n>:SPECtrum:SPAN[:MAXimum]
.........................................................273
[SENSe:]ADEMod<n>:SPECtrum:SPAN:ZOOM
<Span>
This command sets the span (around the center frequency) for RF spectrum result dis-
play.
The span is limited to the demodulation bandwidth (see
Suffix:
<n>
.
irrelevant
Parameters:
<Span>
*RST:
5 MHz
Example:
ADEM:SPEC:SPAN:ZOOM 200 kHz
Sets the rF span to 200 kHz
Manual operation:
See
[SENSe:]ADEMod<n>:SPECtrum:SPAN[:MAXimum]
<FreqRange>
Sets the DBW to the specified value and the span (around the center frequency) of the
RF data to be evaluated to its new maximum (the demodulation bandwidth).
Suffix:
<n>
.
irrelevant
Parameters:
<FreqRange>
*RST:
5 MHz
Default unit: Hz
Manual operation:
See
See
11.4.8.4
(Post-processing) AF Filters
The AF filter reduces the evaluated bandwidth of the demodulated signal and can
define a weighting function. AF filters are only available for AM or FM time domain
evaluations.
[SENSe:]FILTer<n>:AWEighted[:STATe]
..........................................................................274
.............................................................................................. 274
[SENSe:]FILTer<n>:CCIR:WEIGhted[:STATe]
.................................................................. 274
[SENSe:]FILTer<n>:CCIR:[:UNWeighted][:STATe]
............................................................ 275
.............................................................................................. 275
[SENSe:]FILTer<n>:DEMPhasis:TCONstant
.....................................................................275
[SENSe:]FILTer<n>:DEMPhasis[:STATe]
......................................................................... 276
[SENSe:]FILTer<n>:HPASs:FREQuency[:ABSolute]
..........................................................276
[SENSe:]FILTer<n>:HPASs:FREQuency:MANual
............................................................. 276
Configuring the Measurement