Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
210
User Manual 1173.9240.02 ─ 23
Commands for the Analog Baseband calibration signal are described in the R&S
FSW
User Manual.
Remote commands exclusive to Analog Baseband data input and output
........................................................................................... 210
..............................................................................................210
............................................................................................ 210
CALibration:AIQ:HATiming[:STATe]
.................................................................................211
INPut:IQ:BALanced[:STATe]
<State>
This command defines whether the input is provided as a differential signal via all 4
Analog Baseband connectors or as a plain I/Q signal via 2 single-ended lines.
Parameters:
<State>
ON | 1
Differential
OFF | 0
Single ended
*RST:
1
Example:
INP:IQ:BAL OFF
Manual operation:
See
INPut:IQ:FULLscale:AUTO
<State>
This command defines whether the full scale level (i.e. the maximum input power on
the Baseband Input connector) is defined automatically according to the reference
level, or manually.
Parameters:
<State>
ON | 1
Automatic definition
OFF | 0
Manual definition according to
*RST:
1
Example:
INP:IQ:FULL:AUTO OFF
Manual operation:
See
"Full Scale Level Mode / Value"
INPut:IQ:FULLscale[:LEVel]
<PeakVoltage>
This command defines the peak voltage at the Baseband Input connector if the full
scale level is set to manual mode (see
Configuring the Measurement