Remote Commands for Analog Demodulation Measurements
R&S
®
FSW-K7
287
User Manual 1173.9240.02 ─ 23
11.4.10 Configuring Standard Traces
Useful commands for trace configuration described elsewhere
●
DISPlay[:WINDow<n>]:TRACe<t>:Y:SPACing
●
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]
Remote commands exclusive to trace configuration
DISPlay[:WINDow<n>]:TRACe<t>:MODE
.........................................................................287
DISPlay[:WINDow<n>]:TRACe<t>:MODE:HCONtinuous
....................................................288
DISPlay[:WINDow<n>]:TRACe<t>:SELect
........................................................................289
DISPlay[:WINDow<n>]:TRACe<t>[:STATe]
.......................................................................289
[SENSe:]ADEMod<n>:AM[:ABSolute][:TDOMain][:TYPE]
...................................................289
[SENSe:]ADEMod<n>:AM:RELative[:TDOMain][:TYPE]
.....................................................289
[SENSe:]ADEMod<n>:AM:RELative:AFSPectrum[:TYPE]
.................................................. 289
[SENSe:]ADEMod<n>:FM[:TDOMain][:TYPE]
................................................................... 289
[SENSe:]ADEMod<n>:FM:AFSPectrum[:TYPE]
................................................................ 290
[SENSe:]ADEMod<n>:PM[:TDOMain][:TYPE]
...................................................................290
[SENSe:]ADEMod<n>:PM:AFSPectrum[:TYPE]
................................................................ 290
[SENSe:]ADEMod<n>:SPECtrum[:TYPE]
......................................................................... 290
........................................................................................291
..................................................................................292
..........................................................................................292
[SENSe:][WINDow<n>:]DETector<t>[:FUNCtion]
...............................................................292
[SENSe:][WINDow<n>:]DETector<t>[:FUNCtion]:AUTO
.....................................................293
DISPlay[:WINDow<n>]:TRACe<t>:MODE
<Mode>
This command selects the trace mode.
In case of max hold, min hold or average trace mode, you can set the number of single
measurements with
. Note that synchronization to the end of
the measurement is possible only in single sweep mode.
In the Analog Demodulation application when you configure the traces for a window
with a specific evaluation (e.g. AM time domain), the traces in all windows with the
same evaluation are configured identically.
Suffix:
<n>
.
<t>
Configuring the Measurement