Configuration
R&S
®
FSW-K7
51
User Manual 1173.9240.02 ─ 23
5.2 Configuration According to Digital Standards
Access
: "Overview" > "Setup Standard"
Various predefined settings files for common digital standards are provided for use with
the Analog Demodulation application. In addition, you can create your own settings
files for user-specific measurements.
For details on which settings are defined and an overview of predefined standards see
Chapter A.1, "Predefined Standards and Settings"
Selecting the Storage Location - Drive/ Path/ Files
........................................ 51
................................................................................................ 52
................................................................................................ 52
..............................................................................................52
................................................................................... 52
Setup Standard
Opens a file selection dialog box to select a predefined setup file. The predefined set-
tings are configured in the R&S
FSW Analog Demodulation application. This allows for
quick and easy configuration for commonly performed measurements.
Selecting the Storage Location - Drive/ Path/ Files ← Setup Standard
Select the storage location of the file on the instrument or an external drive.
The "Drive" indicates the internal (C:) or any connected external drives (e.g. a USB
storage device).
The "Path" contains the drive and the complete file path to the currently selected
folder.
The "Files" list contains all subfolders and files of the currently selected path.
The default storage location for the settings files is:
C:\R_S\INSTR\USER\predefined\AdemodPredefined
.
Note:
Saving instrument settings in secure user mode.
In secure user mode, settings that are stored on the instrument are stored to volatile
memory, which is restricted to 256
MB. Thus, a "Memory full" error can occur although
the hard disk indicates that storage space is still available.
To store data permanently, select an external storage location such as a USB memory
device.
For details, see "Protecting Data Using the Secure User Mode" in the "Data Manage-
ment" section of the R&S
FSW User Manual.
File Name ← Setup Standard
Contains the name of the data file without the path or extension.
For details on the file name and location, see the "Data Management" topic in the
R&S
FSW User Manual.
Configuration According to Digital Standards