M3SR Series 4100
Changing the Time Request Interval
4.110
Operating Manual 6175.4760.02 – 01
4.4.5.19
Changing the Time Request Interval
Softkey
Selection / Editor
Description
Editor
In the central area the currently active value is
displayed.
1.
Press softkey 'Time REQ INTV'.
2.
Enter a new interval or change interval se-
lectively.
3.
Press 'ENT' to confirm.
The value is now effective.
Possible values:
From 0 (single) up to 255 minutes within a step
width of 1 minute.
When the time quality of a station falls below a
certain threshold, the time acquisition protocol
is started automatically. Using this protocol the
station tries to improve its time quality. The in-
tervals between these attempts can be pro-
grammed via the function 'Time REQ INTV'.
The protocol runs until the time quality reaches
a sufficient value.
If the interval is set to '0', the time request
is switched to ‘single’, so that the operator
is able to make a single time request. If the
softkey ‘Time REQ’ (see
sect. 4.4.5.15 Switching the Time Synchro-
nization On or Off) was already enabled,
the user has to disable it and then enable it
again, in order to perform the single time
request.
Summary of Contents for M3SR 4100 Series
Page 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Page 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Page 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Page 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Page 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Page 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Page 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Page 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...