Operating Manual 6175.4760.02 – 01
5.51
M3SR Series 4100
FastLink Mode (FLM)
1
Network A
2
Network B
3
Network C
4
IDLE
5
BUSY
6
CONNECTED
7
Connecting
8
Rebro-connecting
9
Rebro-busy
Connect request
Request pending
12
Rebro-busy
13
Remote Network C: State is busy
Network C has an active FLM connection.
Now, an application on PC A2 wants to establish an FLM connection to an application run-
ning on PC C2 and issues a 'Connect Request' (CR) command. The state changes from 'Idle'
to 'Connecting'. The CR is answered by the Radio AtoB in Network A with a 'Request Pend-
ing'. When the 'Request Pending' arrives at radio R2, the state changes to 'Rebro-Connect-
ing' and the 'Relative Idle Timeout' value gets updated. In the meanwhile the forwarded CR
traverses Network B and arrives at the Rebroadcast Radio BtoC. This radio knows the cur-
rent state in Network C and answers the CR with 'Rebro-Busy'. When this messages arrives
at the initiating radio R2 in Network A, the state changes from 'Rebro-Connecting' to 'Rebro-
Busy', followed immediately by a state change to 'Idle'.
Summary of Contents for M3SR 4100 Series
Page 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Page 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Page 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Page 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Page 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Page 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Page 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Page 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...