M3SR Series 4100
Rear Cabling for Transceiver
2.10
Operating Manual 6175.4760.02 – 01
2.3.3
Rear Cabling for Transceiver
Connect the mains cable only after all other wiring has been made.
If an external power supply is used to provide the device with extra-low DC voltage
(SELV), the requirements for reinforced or double insulation according to
DIN/EN/IEC 61010 (UL 3111, CSA C22.2 No. 1010.1) or DIN/EN/IEC 60950
(UL 1950, CSA C22.2 No. 950) have to be fulfilled.
Keep off the antenna while transmission is in progress. During transmission danger-
ous high voltages and electromagnetic fields are produced. Respect the instructions
of DIN VDE 0842-2 and the ICNIRP (international commission on non-ionizing radia-
tion protection) guidelines for non-ionizing emission (see www.icnirp.com).
The R&S M3SR Series 4100 radio includes a single mode transceiver, which is a
class 1 laser product. It complies with EN 60825-1 and FDA 21 CFR 1040.10 and
1040.11. The optical connector X21 (RCB SER) of the radio is to be terminated with
another optical connector or with a dust plug.
For detailed information on connectors and contact assignment see the interface de-
scription (sect. 9 Drawings).
Mating connectors are contained in R&S ZF4101 Mating Connector Set (6120.5007.02).
Summary of Contents for M3SR 4100 Series
Page 15: ...M3SR Series 4100 Documentation Overview xiv Operating Manual 6175 4760 02 01...
Page 48: ...M3SR Series 4100 Index 34 Operating Manual 6175 4760 02 01 ZF4401 mod 02 2 10...
Page 70: ...M3SR Series 4100 Radio Control 1 22 Operating Manual 6175 4760 02 01...
Page 116: ...M3SR Series 4100 Example Configuration 2 46 Operating Manual 6175 4760 02 01...
Page 336: ...M3SR Series 4100 Priority Channel 3 220 Operating Manual 6175 4760 02 01...
Page 696: ...M3SR Series 4100 Remote Control 8 4 Operating Manual 6175 4760 02 01...
Page 697: ...Operating Manual 6175 4760 02 01 9 1 M3SR Series 4100 Drawings 9 Drawings...
Page 706: ...M3SR Series 4100 Drawings 9 10 Operating Manual 6175 4760 02 01...