Instrument Functions
R&S
®
NGE100B
36
User Manual 5601.1343.02 ─ 02
The setting of current value corresponds to the I
max
of the respective channel. It is
advisable to set the current limit prior to operating the instrument to prevent damage to
the load and instrument in the case of malfunction like short-circuit.
1. Press
Voltage
or
Current
key.
The previous set channel will be selected.
The channel font changes to blue and all the navigation controls illuminate.
Selected
Voltage
or
Current
key and the channel key are also illuminated.
2. Press the desired channel key to switch to that channel.
Selected channel key (
Ch 1
,
Ch 2
,
Ch 3
) illuminates.
3. Enter the desired voltage or current value.
4. Press the rotary knob,
Voltage
/
Current
or
Enter
key to confirm the value.
The selected channel font text changes to yellow.
Figure 5-10: Voltage and current settings in the instrument
See
on page 31 for alternative way to configure the volt-
age and current values.
See also
on the keypad for setting the fallback time.
5.4.2
Tracking Function
For power supplies with multiple channels, the channels can be linked such that
changes made on one channel are applied to the tracked channel.
For example, the channel 1 output supplies 6 V, intended for digital logic. The other two
supplies 20 V, which can be used with bipolar analog circuitry. The tracking adjust-
ments are applied to the two 20 V supplies so that the + and - 20 V supplies can be
adjusted together.
1. Press
Track
key.
The R&S NGE100B activates the tracking function and the
Track
key illuminates.
Previous selected channel and
Voltage
keys are also illuminated.
2. Press the tracked channels.
The selected tracked channel keys (
Ch 1
,
Ch 2
,
Ch 3
) illuminate.
Basic Functions