Remote Control Commands
R&S
®
NGL200
121
User Manual 1178.8736.02 ─ 02.01
Example:
DATA:DATA? "LOG0001.CSV“,EXT ->
0.019;2.0310;1.000;0.0000;1.000;0.0000;03:45:
29:376
0.020;2.0310;1.000;0.0000;1.000;0.0000;03:45:
30:375
0.020;2.0310;1.000;0.0000;1.000;0.0000;03:45:
31:374
0.020;2.0310;1.000;0.0000;1.000;0.0000;03:45:
32:373
0.019;2.0310;1.000;0.0000;1.000;0.0000;03:45:
33:372
External logging file (USB stick), count = 5.
Return as follows: U1[V];I1[A];U2[V];I2[A];U3[V];I3[A];Timestamp
Usage:
Query only
DATA:DELete
<filename>[,<location>]
Deletes the logging file data values of the selected storage location and file name.
If no storage location is selected, the instrument uses the internal memory. Please
notice that the logging function has to be activated, if you want to use the manual trig-
ger mode (trigger via TRIG button). Without activating the logging function in manual
trigger mode, the instrument is not able to save a logging file internally or on the USB
stick.
Setting parameters:
<filename>
Filename of the logging file data to be deleted.
<location>
INT | EXT | USB
INT
Internal memory
EXT
USB stick
DEF
Internal memory
Example:
DATA:DEL "LOG0001.CSV“,EXT
Delete filename
LOG0001.CSV
from USB stick
Usage:
Setting only
DATA:LIST?
[<location>]
Queries all saved logging files of the selected storage location.
Data and File Management Commands