Operating Basics
R&S
®
NGL200
28
User Manual 1178.8736.02 ─ 02.01
Function
Description
"Over Voltage Protection" (OVP),
If enabled, the icon is highlighted in white.
If triggered, the icon blinks.
Chapter 6.3.2, "Over Voltage Protection
"Over Power Protection" (OPP),
If enabled, the icon is highlighted in white.
If triggered, the icon blinks.
Chapter 6.3.3, "Over Power Protection (OPP)"
"Arbitary Editor" mode,
If enabled, the icon is highlighted in white.
If active, the icon blinks.
"Ramp" mode,
If enabled, the icon is highlighted in white.
If active, the icon blinks.
"Fast Transient Response",
If enabled, the icon is highlighted in white.
The time taken for voltage recovery (<=20 mV)
switches between 30
µ
s and 100
µ
s.
Chapter 6.2.2, "Fast Transient Response"
"Internal Impedance",
If enabled, the icon is highlighted in white.
"Safety Limits",
If enabled, the icon is highlighted in white.
Chapter 6.3.4, "Safety Limits"
"Output Delay",
If enabled, the icon is highlighted in white.
The delay is the time between activation of the out-
put and applying voltage to the output.
Calibration mode,
If user calibration is active, the icon is highlighted in
white.
By default, the factory calibration is in use.
Sense connection,
If sense connection is detected, the icon is highligh-
ted in white.
5.1.2
Channel Display Area
The R&S
NGL200 shows a two channels on the channel display area for NGL202
model and a single channel area display for the R&S NGL201 model. The respective
channel settings and functions are displayed in the individual channel.
Display Overview