Remote Control Commands
R&S
®
NGL200
119
User Manual 1178.8736.02 ─ 02.01
[SOURce:]VOLTage:RAMP[:STATe]
<state>
[SOURce:]VOLTage:RAMP[:STATe]?
Activates/Deactivates or Queries the Ramp function for the previous selected channel.
Parameters:
<state>
0 | 1
0
EasyRamp function will be deactivated.
1
EasyRamp function will be activated.
*RST:
0
Example:
INST OUT1
VOLT:RAMP ON
VOLT:RAMP? -> 1
EasyRamp function of Ch1 is activated
[SOURce:]VOLTage:RAMP:DURation
<duration>
[SOURce:]VOLTage:RAMP:DURation?
Sets/Queries the duration of the voltage ramp.
Parameters:
<duration>
numeric | MIN | MAX | DEFault
numeric
Duration of the ramp function in seconds.
MIN
Minimum duration of the ramp function at 0.00 s.
MAX
Minimum duration of the ramp function at 10 s.
DEF
Default duration of the ramp function at 0.01 s.
Range:
0.01 to 10.00
*RST:
0.01
Default unit: s
Example:
VOLT:RAMP:DUR 4
VOLT:RAMP:DUR? -> 4
Duration of the ramp function is set at 4 s.