Remote Commands Reference
R&S
®
RTC1000
271
User Manual 1335.7352.02 ─ 02
Parameters:
<Polarity>
POSitive | NEGative
POSitive
Rising slope
NEGative
Falling slope
*RST:
NEGative
BUS<b>:SPI:DATA:SOURce
<Source>
Selects the input channel of the data line.
Suffix:
<b>
.
1, 2
Selects the bus.
Parameters:
<Source>
CH1 | CH2 | D0 .... D7
*RST:
CH1
BUS<b>:SPI:DATA:POLarity
<Polarity>
Selects whether transmitted data is high active (high = 1) or low active (low = 1) on the
data line.
Suffix:
<b>
.
1, 2
Selects the bus.
Parameters:
<Polarity>
POSitive | NEGative
POSitive
High active
NEGative
Low active
*RST:
POSitive
BUS<b>:SPI:BORDer
<BitOrder>
Defines if the data of the messages starts with MSB (most significant bit) or LSB (least
significant bit).
Suffix:
<b>
.
1, 2
Selects the bus.
Parameters:
<BitOrder>
MSBFirst | LSBFirst
*RST:
MSBFirst
Protocol Analysis