Remote Control Commands
R&S
®
SGT100A
378
User Manual 1176.8674.02 ─ 07
Example:
BB:ARB:MCAR:EDIT:CARR:STAR 4
the carrier range starts at carrier 2.
BB:ARB:MCAR:EDIT:CARR:STOP 20
the carrier range stops at carrier 20.
BB:ARB:MCAR:EDIT:CARR:STAT ON
sets all the carriers in the carrier range (2 to 20) to ON.
BB:ARB:MCAR:EDIT:CARR:EXEC
transfers the assistant settings for carrier 2 to 20 into the carrier
table.
Usage:
Event
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:FILE
<File>
Selects input file
Parameters:
<File>
string
Example:
BB:ARB:MCAR:EDIT:CARR:FILE "/var/user/IQ_wcdma'
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:EDIT:CARRier:PHASe:STEP
<Step>
The command sets the step width by which the start phases of the carriers in the
defined carrier range will be incremented.
The phase settings are only valid if optimization of the crest factor is disabled
(
:SOURce:BB:ARB:MCARrier:CFACtor:MODE OFF
).
Parameters:
<Step>
float
Range:
-359.99 to 359.99
Increment: 0.01
*RST:
0
Default unit: DEG
Example:
BB:ARB:MCAR:EDIT:CARR:PHAS 90 DEG
sets a start phase of 90° for the carriers in the carrier range.
BB:ARB:MCAR:EDIT:CARR:PHAS:STEP 1 DEG
the start phase is incremented by 1° for each carrier, i.e. the first
carrier has a start phase of 90°, the second a start phase of 91°,
etc.
SOURce Subsystem