Remote Control Commands
R&S
®
SGT100A
395
User Manual 1176.8674.02 ─ 07
Parameters:
<Mode>
OFF | MRK1 | MRK2 | MRK3 | MRK4
OFF
No additional marker is generated.
MRK1|MRK2|MRK3|MRK4
Generates a restart marker signal at the beginning of the first
segment for the corresponding marker.
Use this setting to generate a restart marker for the complete
sequence.
*RST:
OFF
Example:
BB:ARB:WSEG:CONF:SEL 'ConfComm'
BB:ARB:WSEG:CONF:MARK:FSEG MRK3
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:MARKer:MODE
<Mode>
Defines the way the marker information within the separate segments is processed.
Parameters:
<Mode>
IGNore | TAKE
IGNore
The marker information carried in the individual segment wave-
form files is not considered.
TAKE
The output waveform file contains the marker information as
configured in the individual waveform files.
*RST:
TAKE
Example:
BB:ARB:WSEG:CONF:SEL 'ConfComm'
BB:ARB:WSEG:CONF:MARK:MODE TAKE
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:OFILe
<OFile>
Defines the file name for the multi segment waveform. The file extension is
*.wv
.
Parameters:
<OFile>
string
Example:
MMEM:CDIR '/var/user/waveform'
sets the default directory.
BB:ARB:WSEG:CONF:SEL 'multi1'
creates the configuration file
multi1.inf_mswv
in default
directory.
BB:ARB:WSEG:CONF:OFIL 'mseg1_2'
defines the file name
mseg1_2.wv
for the multi segment wave-
form file created using configuration file
multi1.inf_mswv
.
SOURce Subsystem