Varying the RF Signal in List or Sweep Mode
R&S
®
SMA100B
128
User Manual 1178.3834.02 ─ 03
Trigger signal is expected at the INST TRIG connector.
"Positive"
Activates the rising edge of the trigger signal.
"Negative"
Activates the falling edge of the trigger signal.
Remote command:
Reset Sweep
Resets a sweep.
With the next trigger event, the sweep starts at the initial value.
Remote command:
[:SOURce<hw>]:SWEep:RESet[:ALL]
Execute Single Sweep
In "Mode = Single", starts a sweep manually.
Remote command:
[:SOURce<hw>]:SWEep[:FREQuency]:EXECute
[:SOURce<hw>]:SWEep:POWer:EXECute
[:SOURce<hw>]:LFOutput:SWEep[:FREQuency]:EXECute
:TRIGger<hw>[:SWEep][:IMMediate]
:TRIGger<hw>:FSWeep[:IMMediate]
:TRIGger<hw>:PSWeep[:IMMediate]
:TRIGger<hw>:LFFSweep:IMMediate
5.5.2 Frequency Range Settings
Access:
1. Select for example "Sweep" > "RF Frequency Sweep"
2. Select "Frequency Range".
Sweep Mode Settings