Varying the RF Signal in List or Sweep Mode
R&S
®
SMA100B
129
User Manual 1178.3834.02 ─ 03
Settings
Start Frequency/Stop Frequency
............................................................................... 129
.....................................................................................129
Start Frequency/Stop Frequency
Defines the frequency sweep range by setting the start and end values.
See
Chapter 5.2.1, "Correlating Parameters in Sweep Mode"
Remote command:
[:SOURce<hw>]:LFOutput:FREQuency:STARt
[:SOURce<hw>]:LFOutput:FREQuency:STOP
Center Frequency
In "RF Frequency Sweep" mode, sets the RF center frequency.
See
Chapter 5.2.1, "Correlating Parameters in Sweep Mode"
Remote command:
[:SOURce<hw>]:FREQuency:CENTer
Span
In "RF Frequency Sweep" mode, sets the extent of the frequency sweep range.
See
Chapter 5.2.1, "Correlating Parameters in Sweep Mode"
Remote command:
Spacing
In "RF and LF Frequency Sweep" modes, selects the mode for the calculation of the
frequency intervals, with which the current frequency at each step is increased or
decreased.
Enter the step size with the parameter
"Linear"
Takes the frequency value entered as absolute value in Hz.
"Logarithmic"
Takes the value entered as a logarithmic value, i.e. as a constant
fraction of the current frequency in %.
Remote command:
[:SOURce<hw>]:SWEep[:FREQuency]:SPACing
[:SOURce<hw>]:LFOutput:SWEep[:FREQuency]:SPACing
Step Linear/Step Logarithmic
In "RF/LF Frequency Sweep" mode, sets the step width for the individual frequency
sweep steps. The value is added at each sweep step to the current frequency.
Depending on the current
, you can enter either an absolute or logarithmic step
width.
Sweep Mode Settings