Varying the RF Signal in List or Sweep Mode
R&S
®
SMA100B
133
User Manual 1178.3834.02 ─ 03
Remote command:
Mode
Selects the mode for list processing.
For detailed information on the sweep modes and the triggering, see
nal Generation and Triggering in the Sweep and List Modes"
"Auto"
Generates the signal by processing the frequency/level value pairs of
the list from the beginning to the end.
The list steps are performed automatically, controlled by the dwell
time. If you switch from any mode to "Auto", signal generation always
starts at the top of the list.
"Single / Extern Single"
Generates the signal by processing the frequency/level value pairs of
the list once from the beginning to the end after a trigger event.
The list steps are performed automatically, controlled by the dwell
time. If one cycle is completed, the instrument waits for the next trig-
ger event.
"Step / Extern Step"
Generates the signal by processing the frequency/level value pairs of
the list step-by-step, manually triggered.
Remote command:
[:SOURce<hw>]:LIST:TRIGger:SOURce
Dwell Time Mode
Selects either variable dwell times or a fixed dwell time to perform signal generation in
list mode.
"Global"
Uses the same dwell time for all lists steps, set with
.
"From List"
Uses the dwell times from the list.
You can define the dwell time for each frequency/level value pair indi-
vidually, see
Remote command:
Global Dwell Time
Sets the dwell time for
See also
Remote command:
Run Mode
Selects how the instruments process the list data.
List Mode Settings