Clock Synthesis
R&S
®
SMA100B
186
User Manual 1178.3834.02 ─ 03
"Single-Ended/Differential Sine"
Sine signals with user-definable amplitude.
"Differential Square"
Squared signal with fixed amplitude.
"CMOS"
CMOS-like signal with user-definable amplitude and limited frequency
range.
Remote command:
Frequency
Sets the frequency of the generated clock signal.
Min. frequency
Max. frequency
Single-ended sinus
Differential sinus
100 kHz
6 GHz
Differential square
10 MHz
6 GHz
CMOS
100 kHz
200 MHz
Remote command:
Level
For
= "Single-Ended/Differential Sine", sets the amplitude of the gener-
ated clock signal.
Remote command:
DC Offset State
Activates a DC offset for both clock synthesis signal outputs.
The DC offset can be used e.g. to shift the clock synthesis output signal into the trigger
threshold of some logic elements.
Figure 8-1: Example: DC offset = 1.65V and Output Type = Differential Square