Remote Control Commands
R&S
®
SMA100B
381
User Manual 1178.3834.02 ─ 03
[:SOURce<hw>]:PULM:OUTPut:VIDeo:POLarity
<Polarity>
Sets the polarity of the pulse video (modulating) signal, related to the RF (modulated)
signal.
Parameters:
<Polarity>
NORMal | INVerted
NORMal
the video signal follows the RF signal, that means it is high
wihen RF signal is high and vice versa.
INVerted
the video signal follows in inverted mode.
*RST:
NORMal
Example:
See
Example "Perform pulse modulation"
Manual operation:
See
[:SOURce]:PULM[:INTernal][:TRAin]:TRIGger:IMMediate
[:SOURce<hw>]:PULM:STATe
<State>
Activates pulse modulation.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
See
Example "Perform pulse modulation"
Manual operation:
See
[:SOURce<hw>]:PULM:TRIGger:MODE
<Mode>
Selects a trigger mode - auto, external, external single or external gated - for generat-
ing the modulation signal.
Parameters:
<Mode>
AUTO | EXTernal | EGATe | ESINgle
*RST:
AUTO
Example:
See
Example "Perform pulse modulation"
Manual operation:
See
[:SOURce<hw>]:PULM:TTYPe
<Source>
Sets the transition mode for the pulse signal.
SOURce Subsystem