Remote Control Commands
R&S
®
SMA100B
434
User Manual 1178.3834.02 ─ 03
[:SOURce<hw>]:POWer:ATTenuation:RFOFf:MODE
.........................................................436
...............................................................................436
[:SOURce<hw>]:POWer:LBEHaviour
............................................................................... 436
[:SOURce<hw>]:POWer:LIMit[:AMPLitude]
.......................................................................437
..................................................................................... 437
.....................................................................................437
.......................................................................................438
......................................................................................438
.......................................................................................439
........................................................................................439
............................................................................. 439
[:SOURce<hw>]:POWer:STEP[:INCRement]
.................................................................... 440
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:OFFSet
........................................................440
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:RCL
.............................................................441
[:SOURce<hw>]:POWer[:LEVel][:IMMediate][:AMPLitude]
..................................................441
[:SOURce<hw>]:POWer:RANGe:LOWer?
........................................................................ 442
[:SOURce<hw>]:POWer:RANGe:UPPer?
......................................................................... 442
...........................................................................................442
[:SOURce<hw>]:POWer:ALC:DSENsitivity
<Sensitivity>
Sets the sensitivity of the ALC detector.
Parameters:
<Sensitivity>
AUTO | FIXed
AUTO
Selects the optimum sensitivity automatically.
FIXed
Fixes the internal level detector.
*RST:
AUTO
Example:
POW:ALC:DSEN FIX
Manual operation:
See
[:SOURce<hw>]:POWer:ALC:OMODe
<OffMode>
Sets the level control mode. It is activated when automatic level control is switched off
(ALC Off).
Parameters:
<OffMode>
SHOLd
Activates level control temporarily, when the level or frequency
changes ("ALC Off Sample & Hold").
*RST:
SHOLd
Example:
POW:ALC OFF
Deactivates automatic level control at the RF output.
POW:ALC:OMOD SHOL
Activates the level control briefly when changing the frequency
or level.
SOURce Subsystem