Remote Control Commands
R&S
®
SMA100B
446
User Manual 1178.3834.02 ─ 03
Parameters:
<OutpFreqMode>
DER10M | DER100M | OFF | LOOPthrough
OFF
Disables the output.
DER10M|DER100M
Sets the output reference frequency to 10 MHz or 100 MHz.
The reference frequency is derived from the internal reference
frequency.
LOOPthrough
Forwards the input reference frequency to the reference fre-
quency output.
*RST:
n.a. (factory preset: DER10M)
Example:
See
Example "Configuring the reference oscillator"
Manual operation:
See
"Reference Output/1GHz Reference Output"
[:SOURce]:ROSCillator:OUTPut:ALTernate:FREQuency:MODE
<OutpFreqMode>
Sets the output reference frequency.
Parameters:
<OutpFreqMode>
LOOPthrough | DER1G | OFF
OFF
Disables the output.
DER1G
Sets the output reference frequency to 1 GHz.
The reference frequency is derived from the internal reference
frequency.
LOOPthrough
Forwards the 1 GHz input reference frequency to the reference
frequency output.
*RST:
n.a. (factory preset: OFF)
Example:
See
Example "Configuring the reference oscillator"
Manual operation:
See
"Reference Output/1GHz Reference Output"
[:SOURce]:ROSCillator[:INTernal]:ADJust:VALue
<Value>
Specifies the frequency correction value (adjustment value).
Parameters:
<Value>
integer
*RST:
0
Example:
See
[:SOURce]:ROSCillator[:INTernal]:ADJust[:
Manual operation:
See
SOURce Subsystem