Remote Control Commands
R&S
®
SMA100B
452
User Manual 1178.3834.02 ─ 03
Manual operation:
See
[:SOURce<hw>]:SWEep[:FREQuency]:MODE
<Mode>
Sets the cycle mode for the frequency sweep.
Parameters:
<Mode>
AUTO | MANual | STEP
AUTO
Each trigger event triggers exactly one complete sweep.
MANual
The trigger system is not active. You can trigger every step indi-
vidually by input of the frequencies with the command
STEP
Each trigger event triggers one sweep step. The frequency
increases by the value entered with
SOURce<hw>]:SWEep[:FREQuency]:STEP:LOGarithmic
(logarithmic spacing).
*RST:
AUTO
Example:
See
Example "Setup an RF frequency or power sweep"
Manual operation:
See
[:SOURce<hw>]:SWEep[:FREQuency]:POINts
<Points>
Sets the number of steps within the RF frequency sweep range.
See
Chapter 5.2.1, "Correlating Parameters in Sweep Mode"
Two separate
POINts
values are used for linear or logarithmic sweep spacing (
SOURce<hw>]:SWEep[:FREQuency]:SPACing
affects the currently set sweep spacing.
Parameters:
<Points>
integer
Range:
2 to Max
Example:
See
Example "Setup an RF frequency or power sweep"
[:SOURce<hw>]:SWEep[:FREQuency]:SPACing
<Spacing>
Selects the mode for the calculation of the frequency intervals, with which the current
frequency at each step is increased or decreased.
The keyword
[:FREQuency]
can be omitted; then the command is SCPI-compliant.
SOURce Subsystem