Remote Control Commands
R&S
®
SMA100B
369
User Manual 1178.3834.02 ─ 03
Suffix:
<ch>
.
1 to 2
Modulation signal channel
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
See
Example "Creating an amplitude modulated RF signal"
Manual operation:
See
[:SOURce<hw>]:AM<ch>[:DEPTh]
<Depth>
Sets the depth of the amplitude modulation in percent.
Suffix:
<ch>
.
1 to 2
Modulation signal channel
Parameters:
<Depth>
float
Range:
0 to 100
Increment: 0.1
Example:
See
Example "Creating an amplitude modulated RF signal"
Manual operation:
See
[:SOURce<hw>]:AM:EXTernal:COUPling
<Coupling>
Selects the coupling mode for the external modulation input in case of amplitude mod-
ulation.
Parameters:
<Coupling>
AC | DC
AC
Passes the AC signal component of the modulation signal.
DC
Passes the modulation signal with both components, AC and
DC.
*RST:
AC
Example:
:SOURce:AM:EXTernal:COUPling AC
12.15.1.3
SOURce:FM Subsystem
Option: R&S
SMAB-K720
The FM subsystem contains the commands for setting the frequency modulation.