Performing DVB-C signal generation tasks
R&S
®
SMCVB-K157
39
User Manual 1179.4686.02 ─ 01
4.1.2
How to apply an external TS input signal
To connect to the external TS input interface
1. Use a double-shielded 75
Ω
BNC cable for connection between R&S
SMCV100B
See also Section "Cable selection and electromagnetic interference (EMI)" in the
R&S
SMCV100B Getting Started user manual.
2. At the R&S
SMCV100B, connect the cable to the "User 1" connector.
The connector is on the rear panel of the R&S
SMCV100B.
How to: Section "To connect to non-screwable connectors (BNC)" in the
R&S
SMCV100B Getting Started user manual.
To specify the TS input interface at the R&S
SMCV100B
The R&S
SMCV100B is
TS data source via the "User 1" con-
nector.
1. Select "Input Signal > General > Source > External".
2. Select "General > Global Connectors".
3. In the "Global Connectors" dialog, configure the "User 1" connector for a TS input
signal:
a) Select "Direction > Input".
b) Select "Signal > TS".
To configure an external TS input signal
The R&S
SMCV100B is
for receiving a TS input signal at the "User 1" con-
nector.
1. Specify general TS input signal properties:
a) Select "Input Signal > General > Source > External".
b) Select "Input > TS IN".
c) Specify the format of the input signal:
● Select "ASI", if you have a source supporting
format.
● Select "SMPTE 310", if you have a source supporting
2. Optionally, activate "Stuffing" to adjust the TS data rate.
Configuring the input signal