Remote-control commands
R&S
®
SMCVB-K157
66
User Manual 1179.4686.02 ─ 01
Parameters:
<TSRate>
integer
Range:
1 to 35E7
*RST:
5018502
Example:
See
Example "Configuring and monitoring TS player output"
Manual operation:
See
:TSGen:READ:FMEMory
<FMemory>
Queries the file size of the TS player file.
Parameters:
<FMemory>
integer
Range:
0 to 10
*RST:
0
Example:
See
Example "Configuring and monitoring TS player output"
Manual operation:
See
:TSGen:READ:ORIGtsrate
<ORIGtsrate>
Displays the calculated original TS
data rate.
Parameters:
<ORIGtsrate>
integer
Range:
1 to 350000000
*RST:
5018502
Example:
See
Example "Configuring and monitoring TS player output"
Manual operation:
See
:TSGen:READ:PLAYfile:LENGth?
Queries calculated original loop time.
Return values:
<Length>
integer
Range:
0 to 100
*RST:
0
Example:
See
Example "Configuring and monitoring TS player output"
Usage:
Query only
Manual operation:
See
TSGen subsystem