ATSC-M/H Configuration and Settings
R&S
®
SMCVB-K161
17
User Manual 1179.1035.02 ─ 02
If "Stuffing > Off", the value indicates the transport stream input data rate that is
required for the transport stream.
If "Stuffing > On", the value indicates the maximum useful data rate, that is allowed in
the transport stream.
If "Stuffing > Off", the value indicates the transport stream input data rate that is
required for the transport stream.
Remote command:
[:SOURce<hw>]:BB:ATSM:USEFul[:RATE]:MAX?
Measured Data Rate
Requires "Source > External".
Displays the measured value of the data rate r
meas
of one of the following:
●
External transport stream including null packets input at "User 1" connector
●
External transport stream including null packets input at "IP Data/LAN" connector
(TSoverIP)
The value r
meas
equals the sum of useful data rate r
useful
and the rate of null packets r
0
:
If "Stuffing > Off", ensure that the measured data rate equals the maximum useful data
rate (r
meas
= r
max. useful
).
If "Stuffing > Off", ensure that r
meas
= r
max. useful
.
Remote command:
[:SOURce<hw>]:BB:ATSM[:INPut]:DATarate?
Useful Data Rate
Requires "Source > External/TS Player".
Displays the data rate of useful data r
useful
of the external transport stream. The data
rate is measured at the input of the installed input interface.
Remote command:
[:SOURce<hw>]:BB:ATSM:USEFul[:RATE]?