Remote-Control Commands
R&S
®
SMCVB-K164
83
User Manual 1179.0974.02 ─ 02
Parameters:
<Dvbt2InpFormat>
ASI | SMPTE
*RST:
ASI
Example:
See
Example "Configuring general input signal properties"
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:ANALyzer?
Queries the status of the T2-MI analyzer by an error message.
Return values:
<Analyzer>
string
No error
Implies correct behavior of the analyzer.
*RST:
No error
Example:
See
Example "Querying general T2-MI interface parameters"
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:INTerface
<Interface>
Activates the T2-MI modulator interface.
Parameters:
<Interface>
0 | 1 | OFF | ON
*RST:
0
Example:
See
Example "Querying general T2-MI interface parameters"
Example:
See
Example "Querying T2-MI packet timing parameters"
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:PID
<Pid>
.
The PID belongs to MPEG transport stream packets, that contain T2-MI data.
Parameters:
<Pid>
integer
Range:
#H0 to #H1FFF
*RST:
#H1000
Input Commands