Remote-Control Commands
R&S
®
SMCVB-K164
90
User Manual 1179.0974.02 ─ 02
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:MAX:T2?
[:SOURce<hw>]:BB:T2DVb:INPut:T2MI:MAX:T1?
Queries the current value of the maximum time parameters T
max1
/T
max2
/T
max3
/T
max4
.
Return values:
<MaxT1>
float
Range:
-99.999999 to 99.999999
Increment: 0.000001
*RST:
0
Default unit: s
Example:
See
Example "Querying T2-MI packet timing parameters"
Usage:
Query only
Manual operation:
See
6.2.4
Test Signal Commands
Example: Configuring test signal properties
:SOURce1:BB:T2DVb:INPut:T2MI:INTerface 0
:SOURce1:BB:T2DVb:SOURce TEST
:SOURce1:BB:T2DVb:PLP1:INPut:TESTsignal?
// Response: "TTSP"
:SOURce1:BB:T2DVb:PLP1:INPut:FORMat?
// Response: "TS"
********************************************************************************
// Configure test signal properties.
********************************************************************************
:SOURce1:BB:T2DVb:TSPacket H184
:SOURce1:BB:T2DVb:PIDTestpack NULL
:SOURce1:BB:T2DVb:PID?
// Response: "8191" in decimal representation
// "1FFF" in hexadecimal representation
:SOURce1:BB:T2DVb:PIDTestpack VAR
:SOURce1:BB:T2DVb:PID 4607
// Corresponds to "11FF" in hexadecimal representation
:SOURce1:BB:T2DVb:PAYLoad PRBS
:SOURce1:BB:T2DVb:PRBS P23_1
Commands
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:INPut:TESTsignal
...................................................... 91
[:SOURce<hw>]:BB:T2DVb:PAYLoad
.................................................................................91
........................................................................................ 91
Input Commands