Remote-Control Commands
R&S
®
SMCVB-K164
104
User Manual 1179.0974.02 ─ 02
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:FECFrame
<NPFecFrame>
Sets the FEC frame.
Parameters:
<NPFecFrame>
NORMal | SHORt
NORMal
N
LDPC
= 64800
SHORt
N
LDPC
= 16200
*RST:
NORMal
Example:
See
Example "Configure BICM parameters"
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:FRAMeindex
<FFIndex>
Queries the index of the first frame of the super frame, in that the current PLP occurs.
Parameters:
<FFIndex>
integer
Range:
0 to 255
*RST:
0
Example:
See
Example "Configure BICM parameters"
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:MAXBlocks?
Queries the maximum number of FEC blocks per interleaving frame.
Return values:
<FECBlocksMax>
integer
Range:
0 to 1023
*RST:
0
Example:
See
Example "Configure BICM parameters"
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:RATE
<Coderate>
Sets the code rate.
Parameters:
<Coderate>
R1_2 | R3_5 | R2_3 | R3_4 | R4_5 | R5_6 | R1_3 | R2_5
*RST:
R3_5
Example:
See
Example "Configure BICM parameters"
BICM Commands