DVB-T2 Configuration and Settings
R&S
®
SMCVB-K164
18
User Manual 1179.0974.02 ─ 02
"External"
Uses a transport stream, that is input at the "TS IN"/"IP Data" inter-
face.
For more information about connecting to the interfaces, see also:
●
"TS IN" interface: Section "Configuring the Global Connectors" in
the R&S
SMCV100B user manual.
●
Chapter 4.12, "Local IP Data Network Set-
"TS Player"
Uses an internal transport stream with TS packet data played from a
file. The player requires no option.
Playing encrypted files with extension
_c
requires a stream library
option R&S
SMCVB-KSx.
See also:
●
●
Supported TS player file types
"Test Signal"
Requires "T2-MI Interface > Off".
Uses an internal test signal as specified in
Remote command:
Number of PLPs
Displays the number of
s.
The available number of PLPs depends on the setting of "T2-MI Interface":
●
If "T2-MI Interface > Off", the number of PLPs is "1" (single PLP).
●
If "T2-MI Interface > On", maximum "1 to 20" PLPs are supported.
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:NPLP?
Input
Requires "Source > External".
Sets the external input interface.
"TS IN"
Input for serial transport stream data. The signal is input at the "User
1" connector.
"IP"
Input for IP-based transport stream data (TSoverIP). The signal is
input at the "IP Data" connector.
Remote command:
Input Format
Requires "Source > External" and "Input > TS IN".
Sets the format of the input signal.
"ASI"
format
"SMPTE 310"
Remote command:
[:SOURce<hw>]:BB:T2DVb:INPut:FORMat