Remote-Control Commands
R&S
®
SMCVB-K167
55
User Manual 1179.1058.02 ─ 02
Parameters:
<RollOff>
0.20 | 0.25 | 0.35
*RST:
0.35
Manual operation:
See
[:SOURce<hw>]:BB:DVBS:SYMBols
<Symbolrate>
Sets the symbol rate.
Parameters:
<Symbolrate>
integer
Range:
1.00E+05 to 9.00E+07
*RST:
27.5e6
Manual operation:
See
6.4
Special Commands
[:SOURce<hw>]:BB:DVBS[:SPECial]:SETTings[:STATe]
...................................................... 55
[:SOURce<hw>]:BB:DVBS[:SPECial]:REEDsolomon
........................................................... 55
[:SOURce<hw>]:BB:DVBS[:SPECial]:SETTings[:STATe]
<SpecialState>
Enables/disables special settings.
The setting allows you to switch between standard-compliant and user-defined channel
coding.
Parameters:
<SpecialState>
0 | 1 | OFF | ON
*RST:
0
Manual operation:
See
[:SOURce<hw>]:BB:DVBS[:SPECial]:REEDsolomon
<ReedSolomon>
Enables the Reed-Solomon encoder. The standard stipulates a Reed-Solomon RS
(204, 188).
Parameters:
<ReedSolomon>
0 | 1 | OFF | ON
*RST:
1
Manual operation:
See
Special Commands