Preparing for Use
R&S
®
SMCV100B
25
Getting Started 1432.7046.02 ─ 02
a) Turn the adapter, so that the release bracket joints show upwards.
b) At the RJ-45 socket of the adapter, open the release bracket, so that the
bracket shows upward.
c) Insert and push the adapter into the cage of the SFP+ socket of the "IP
Data" connector.
d) To mount the adapter, push the release bracket down to close the bracket.
The adapter is connected to the "IP Data" connector.
3. Plug the RJ-45 cable into the RJ-45 socket of the adapter.
To disconnect from IP Data interface
1. Unplug the RJ-45 cable.
2. Open the release bracket.
3. Carefully pull the SFP+ to RJ-45 adapter out of the SFP+ socket of the "IP
Data" interface.
Use the "IP Data" interface as input of external coding IP data for broadcast base-
band signals.
See also chapter "Local IP Data Network Settings" in the corresponding broad-
cast standard user manuals.
4.14
Switching On or Off
The following table provides an overview of power states, LEDs and power switch
positions.
Table 4-1: Overview of power states
State
LED
Position of power switch
Off
gray
[0]
Standby
orange
[I]
Ready
green
[I]
Switching On or Off