Troubleshooting
R&S
®
TSMA6
101
User Manual 4900.8057.02 ─ 06
● If the "Mode of Operation" != "PC Mode", switch mode to "PC Mode". Restart
the R&S
TSMA6 via web GUI and check the LEDs, see
● If the IP address of the "SCAN Port (int)" = "192.168.0.1", continue with
.
● If the IP address of the "SCAN Port (int)" != "192.168.0.1", contact R&S sup-
port.
4. Check the scanner [State] LED.
● If it is off, continue with
5. The scanner module may be blocked due to a program in Windows "Startup".
To open the "Startup" folder, press
W R
to open the "Run" dialog box, type
in
shell:startup
and then press "OK".
An explorer window right to the "Startup" folder opens.
● Remove any program entry which could interface the scanner module, restart
the R&S
TSMA6 via the web GUI and repeat with
● If there is no entry, contact R&S support.
6. Start the "TSME Device Manager" via the Windows "Start" menu.
"Start > All Programs > TsmeTools > TsmeDeviceManager"
Scanner Is Not Found from Software (R&S ROMES, R&S NESTOR)