Usage of the Web GUI
R&S
®
TSMA6
124
User Manual 4900.8057.02 ─ 06
A.2.1.1
Mode
The "Mode" tab displays information about the operation mode and the state of the cur-
rent measurement.
Mode of Operation
With the "Mode of Operation", the autostart sequence of the R&S
TSMA6 can be
adjusted to change the usage of the R&S
TSMA6.
Current Measurement
Displays information about the state of the current measurement.
A.2.1.2
Power
The "Power" tab displays all settings related to the power on/power off scenarios.
............................................................................................. 124
................................................................................... 124
..............................................................................................125
Startup Settings
Configures different startup sequences.
Auto Power ON ← Startup Settings
The R&S
TSMA6 starts automatically when power is applied at the DC IN connector of
the R&S
TSMA6 or at the DC IN connector of a connected R&S
TSMA6 Battery Pack.
Remember Last State ← Startup Settings
The R&S
TSMA6 remembers the last state before the DC power was removed.
When DC power is applied again at the DC IN connector of the R&S
TSMA6 or at the
DC IN connector of a connected R&S
TSMA6 Battery Pack, the power state before
power removal is recovered.
Delayed System Start
Configure the power on delay (in min) and press "Activate".
The device goes in standby mode and starts automatically after the configured delay
with the preconfigured measurement mode.
Configuration