Troubleshooting
R&S
®
TSMA6
93
User Manual 4900.8057.02 ─ 06
8
Troubleshooting
For all troubleshooting procedures, connect keyboard, mouse and a monitor to the
R&S
TSMA6.
...............................................................................................93
.............................................................................................. 94
Verify Scanner Link / Recall Device Info Using TsmeDeviceManager
TSMA6 Automatically Switches Off After Power On
.......................................98
Scanner Is Not Found from Software (R&S ROMES, R&S NESTOR)
Verify Scanner Connection LAN Settings
..............................................................102
.................................................................................................104
.......................................................................... 105
WLAN Access Point Not Detected By External PC, Mobile Or Tablet
Web GUI not Accessible via WLAN
.......................................................................111
Web GUI Locally Not Accessible
...........................................................................112
......................................................................... 114
................................................... 116
............................................................................... 118
8.1
LED Indicated Errors
●
"Mode" LED blue blinking fast
−
Selftest Error
–
Check the scanner connection (see
Chapter 8.6, "Verify Scanner Connection
–
Evaluate the
Selftestresult.txt
Chapter 8.2, "Evaluate Selftest
●
"State" LED red blinking (2 Hz)
−
Temperature Warning
–
Check the ventilation openings and the operating temperature.
–
Switch off the device and let it cool down.
●
"State" LED red continuous
−
Overheated Unit
–
Switch off the device and let it cool down.
–
Check the ventilation openings and switch on the device. If the problem occurs
again, analyze the
Selftestresult.txt
(see
●
"Meas" LED red blinking (2 Hz)
−
Application Error
–
Refer to the application note of the used software.
●
"Pwr" LED off after startup
−
Power Error
–
Contact R&S support.
LED Indicated Errors