Key features

R&S

®

ZN-Z15x

4

User Manual 1337.5963.02 ─ 04

1.1

 

Labels on the product

Labels on the casing inform about:

Product and environment safety

Identification of the product

Table 1-1: Labels regarding product and environment safety

Potential hazard
Read the product documentation to avoid product damage.

Take care when handling electrostatic sensitive devices.

Labeling in line with EN 50419 for disposal of electrical and electronic equipment after

the product has come to the end of its service life. For more information, see the prod-

uct user manual, chapter "Disposal".

1.2

 

Warning messages in the documentation

A warning message points out a risk or danger that you need to be aware of. The
signal word indicates the severity of the safety hazard and how likely it will occur
if you do not follow the safety precautions.

NOTICE

Potential risks of damage. Could result in damage to the supported product or to
other property.

2

 

Key features

A calibration unit enables the automatic calibration of several network analyzer
ports in one simple procedure. It contains calibration standards that are electroni-
cally switched by the analyzer firmware, when a calibration is performed. The
characteristic data of these standards is stored in the calibration unit, so that the
analyzer can calculate the error terms and apply the calibration without any fur-
ther input.

Summary of Contents for ZN-Z15 Series

Page 1: ...R S ZN Z15x Calibration Units User Manual 1337596302 Version 04 U 2...

Page 2: ...f 2 ports 5 GHz to 67 GHz 1332 7239 02 R S ZN Z156 1 85 mm f 2 ports 10 MHz to 67 GHz 1332 7239 03 User manual 1326 5080 02 covers the R S ZN Z154 calibration unit 2022 Rohde Schwarz GmbH Co KG Muehl...

Page 3: ...roduction and verification of electronic components and devices in industrial administrative and laboratory environments Use the R S ZN Z15x only for its designated purpose Observe the operating condi...

Page 4: ...ning messages in the documentation A warning message points out a risk or danger that you need to be aware of The signal word indicates the severity of the safety hazard and how likely it will occur i...

Page 5: ...do not wear out because they are switched electroni cally The R S ZN Z15x calibration units differ in the number of calibration ports and the connector types For an overview refer to the data sheet 3...

Page 6: ...esidential buildings Class A equipment is intended for use in industrial environments It can cause radio disturbances in residential environments due to possible conducted and radiated disturbances It...

Page 7: ...nts of the product and the device under test DUT Ground yourself to prevent electrostatic discharge damage a Use a wrist strap and cord to connect yourself to ground b Use a conductive floor mat and h...

Page 8: ...See also Cable selection and electromagnetic interference EMI on page 6 3 5 RF connections The calibration unit provides two RF connectors numbered 1 to 2 to be connec ted to the test ports of the ana...

Page 9: ...ialization the status LED will switch to green see Chapter 4 2 Function of the status LED on page 9 The unit is ready to use as outlined below 4 2 Function of the status LED The LED on top of the Cali...

Page 10: ...ssignment a Connect the calibration unit ports to the test ports of the network analyzer as depicted in the analyzer GUI b Start the calibration data acquisition 4 Disconnect the RF ports of the calib...

Page 11: ...of your network analyzer for this purpose For details refer to the analyzer s help system 4 5 microSD card On the rear of the R S ZN Z152 and R S ZN Z153 calibration units there is a microSD card slot...

Page 12: ...ct contact our customer support center A team of highly qualified engineers provides support and works with you to find a solution to your query on any aspect of the operation program ming or applicat...