Command reference
R&S
®
ZNB/ZNBT
988
User Manual 1173.9163.02 ─ 62
Use
CALCulate<Chn>:STATistics:NLINear:COMP:RESult?
to retrieve the
compression results.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
dBValue
Compression value
Example:
See
CALCulate<Chn>:STATistics:NLINear:COMP:
Manual operation:
See
CALCulate<Chn>:STATistics:NLINear:COMP:PHASe
<PhaseValue>
Defines the compression value x for the compression point measurement for phase
formatted traces.
Use
CALCulate<Chn>:STATistics:NLINear:COMP:RESult?
to retrieve the
compression results.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<PhaseValue>
Compression value
Default unit: deg
Manual operation:
See
CALCulate<Chn>:STATistics:NLINear:COMP:RDOMain:USER
<RefRange>
Selects one of the 10 channel-specific user defined ranges as the reference range for
compression point calculation.
CALCulate<Chn>:STATistics:NLINear:COMP:REFerence
to
RANGe
.
The selected range can then be configured with the
STATistics:NLINear:COMP:RDOMain:USER:STARt
STATistics:NLINear:COMP:RDOMain:USER:STOP
, and
STATistics:NLINear:COMP:RDOMain:USER:SHOW
commands.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<RefRange>
Range number
Range:
1 to 10. In addition, 0 denotes the (non-configura-
ble) "Full Span" evaluation range.
*RST:
0
Manual operation:
See