background image

Manual-1

OPERATORS  MANUAL

CP 64

COMMERCIAL PROCESSOR

QUICK START

If you were the type that cheated on school book reports by just skimming through the reading assignments, then this

section is for you! It gives you not quite enough information to really know what you’re doing. But, if you follow the
recommended set up procedure, you should get at least a “B.”

Keep the amplifiers and the CP 64 turned off until all connections are made.

INTERNAL SETTINGS:

 Access to the following internal controls requires removal of the top cover. All internal

settings should be complete before you install the CP 64. The factory default settings work for many applications. How-
ever, you may need to change one or more for your system. See the INTERNAL ADJUSTMENTS description on page
Manual-8 for more details
• Each Page Input has a 15 volt Phantom Power switch. The default is off.
• The Page Priority switch assigns priority override to Page 1, Page 2 or NO (none). The default is Page 1. If a Page has

priority, it overrides the non-priority Page in the Zone(s) it is assigned. The NO priority setting allows the Pagers to mix.

• Each Page Input may sum with the Program Pre- or Post-VCA. When set to Pre-VCA, Zone Level, EQ and Limiter

circuits act upon the Page. When summed Post-VCA, the Page is not influenced by Zone Level, EQ or Limiter circuits.
The default is Pre-VCA.

• The Zone 1 Stereo/Mono switch default is Stereo.
• There are two internal trim controls for the Program Priority detector. The Program Priority Threshold trim has a range

of -

 to -35 dBu with a default of -50 dBu. The Program Priority Release Time has a range of 2 to 20 seconds. The

default is 12 seconds.

PAGE INPUTS: 

 Connect Page Inputs to the Euroblock on the rear panel and select the appropriate 

MIC 

or 

LINE

switch position for each. First, set the gain with the Page 

TRIM 

control, then set the Page 

DETECT THRESHOLD

 and

finally the Page Zone 

LEVEL

.

PR 2 REMOTE:

  If you use the optional PR 2 remote (sold separately), wire it to the rear 

RMT ZONE ASSIGN

Euroblock as indicated. If you require remote control but do not wish to use a PR 2, any simple switch closure to GND will
work. These inputs are also TTL compatible (0 to 5 VDC). See wiring details on pages Manual 9-10.

PROGRAM INPUTS:

  Connect Program sources to the RCA 

PROGRAM INPUTS

 (L1, L2, L3 & P.) If you have a

priority program, like a jukebox, connect it to the 

PRIORITY 

Input. The Program PRIORI

TY ASSIGN 

switch assigns

priority override to Off, Zone 1Zone 2, or Both. In the Zone(s) that it is assigned, the priority program is automatically
selected when signal is detected.

EXPAND OUTPUTS:

  Wire the 

EXPAND OUTPUT

 Euroblock for each Zone as required. These are cross-coupled

line drivers and may be used balanced or unbalanced. Each Expand Output can be Page-only, Program-only or Zone
signal. The Zone source will not include the Page if the Page is summed Post-VCA. Page is always available from the Page
source.

ZONE OUTPUTS: 

 Wire the two 

ZONE OUT 

Euroblocks as required. These are cross-coupled line drivers and may

be used balanced or unbalanced. Set the 

LIMIT

 threshold as required.

ZR 1 REMOTE:

  You may use one or two ZR 1 Remotes with each CP 64. If you use the optional ZR 1 remote (sold

separately), wire it to the rear 

REMOTES 

Euroblock as indicated. If a ZR 1 remote is not used, any simple switch closure

to GND will work for the D0 and D1 pins. These pins are TTL compatible (0 to 5 VDC). The logic is inverse Gray Code.
Any ground referenced 5 volt DC control may be used as the input to V

1

 or V

2

. Do not ground the Vr

1

 or Vr

2

 pins. See

wiring details on pages Manual 9-10.

The CP 64 is very versatile. While this makes a large number of system applications possible, it also results in complex-

ity. For this reason, it is important to use an organized approach for setup and calibration. A highly recommended setup
procedure appears on page Manual-11. By following it you will encounter fewer problems and reduce the need to increase
our collective phone bills.

WEAR PARTS:

 This product contains no wear parts.

Summary of Contents for CP 64

Page 1: ...REMOTE If you use the optional PR 2 remote sold separately wire it to the rear RMT ZONE ASSIGN Euroblock as indicated If you require remote control but do not wish to use a PR 2 any simple switch clos...

Page 2: ...itches assign one of four Program Inputs in each Zone ZONE RMT switches when pushed in enable the Remotes port for a Zone This turns control of Zone Level and Zone Program Select over to the Remotes p...

Page 3: ...Expand Output PROGRAM PRIORITY ASSIGN switch determines in which Zone s the automatic priority override is enabled Off none Zone 1 Zone 2 or Both are the possible settings If you do not intend to use...

Page 4: ...ea page or BOTH for all page Zone 1 karaoke ZR 1 Remote Set PROGRAM SELECT to L1 Adjust LEVEL as needed Set both front panel Zone RMT switches in to enable the Zone Remotes When a priority program juk...

Page 5: ...t control of Zone level and Page level Set the Program PRIORITY ASSIGN switch to Zone 2 This sends pre recorded advertisements or break bell tones to the retail space or shop floor respectively You ma...

Page 6: ...mmended with Program audio inputs driven from long cable lines This is also true for audio sources fed from satellite systems like DSS DMX Primestar AEI TV Cable etc Cable systems are generally earth...

Page 7: ...HANNEL AMPLIFIER OFFICES SALES CREDIT ZR1 MA 3 RIGHT SALES FLOOR DISTRIBUTED ZR1 8 Ohm 70V 8 Ohm PROMO VCR LEFT PRIORITY 2 SERVICE RECEPTION PR2 TUNER OPTIONAL SOURCES PRIORITY 3 PRIORITY 4 HOLE PLUG...

Page 8: ...of the Page Inputs as a Priority Page Input The Priority Pager overrides the non priority Pager in the Zone s it is assigned It is important to note that the non priority Pager may still broadcast in...

Page 9: ...nal hot and the shield gnd wire to ground When unbalanced wiring is used it is very important for the CP 64 and any other unit in the system to have good earth or technical grounds If a unit is locate...

Page 10: ...e front panel of the remote assembly Install any Decora plate of your choice For a secured installation you may wish to leave the knobs off and use a blank Decora plate to cover the remote after adjus...

Page 11: ...ts Page settings repeat for second page input Input Pad Mic Line as required Input gain trim Center 12 00 Detector Threshold Min ccw Active Paging assign Both Paging Level Zone 1 Min Paging Level Zone...

Page 12: ...Detect Threshold rear panel so the Active indicator front panel lights only when you speak If the Page Detect Threshold is set too low the Pager may gate on due to background sound Repeat for second M...