REMOTE MOUNTING

The ZR 1 and PR 2 remote assemblies mount in a standard

U.S. electrical box with a minimum depth of 2.25". Be sure to
note the wire color of each input in order to facilitate correct
wiring to the CP 64. Connect each wire to the 5-pin connector
by fully inserting it in the correct socket and tightening the
screw. Make sure wires are free of nicks and that the cable
jacket is stripped back sufficiently to allow it to lie in the
electrical box with the remote assembly inserted. Use the flat
head #6 screws supplied with the kit to mount the remote
assembly and silk-screened front panel to the electrical box
(see above diagram). Note the “UP” arrow screened on the
printed circuit board of each remote (it should mount pointing
up).

The silk-screened front panel metal is painted on both

sides. This allows you to custom silk-screen the panel or add
your own custom decals. Simply install the modified front
panel with your art facing out, and you are in business!

Install each knob so that the line on the knob is properly

aligned with the silk-screening on the front panel of the
remote assembly. Install any Decora plate of your choice. For
a secured installation, you may wish to leave the knobs off
and use a blank Decora plate to cover the remote after
adjustment.

WIRE TYPES

Variations in wire type do not greatly affect the perfor-

mance of the remote controls. However, 22-gauge stranded
wire with a flexible jacket is recommended. You may use 5-
conductor unshielded remote control signal cable for shorter
runs (less than 200 ft.) or 4-conductor (2 pair) shielded
remote control signal cable (use the shield as the GND return)
for longer runs (200 to 1000 ft.). The type of wire required is
influenced by your installation and local electrical codes.

Rane Corporation does not provide or source cable. Please

contact your local retail or wholesale outlet, not the factory.
The following is a short list of suitable cable types:

CONSOLIDATED ELECTRONIC WIRE AND CABLE
Plenum cable:
Unshielded remote control signal cable CAT. # 9896
Shielded remote control signal cable CAT. #9877, CAT. #9852

WEICO WIRE & CABLE INC.
Communication and control cable:
Multiconductor, unshielded CAT. #7606

ALPHA
Communication and control cable:
Multiconductor, unshielded CAT. #1175C

BELDEN
Unshielded remote control signal cable CAT. # 88741
Shielded remote control signal cable CAT. # 88723

Summary of Contents for CP 64

Page 1: ...REMOTE If you use the optional PR 2 remote sold separately wire it to the rear RMT ZONE ASSIGN Euroblock as indicated If you require remote control but do not wish to use a PR 2 any simple switch clos...

Page 2: ...itches assign one of four Program Inputs in each Zone ZONE RMT switches when pushed in enable the Remotes port for a Zone This turns control of Zone Level and Zone Program Select over to the Remotes p...

Page 3: ...Expand Output PROGRAM PRIORITY ASSIGN switch determines in which Zone s the automatic priority override is enabled Off none Zone 1 Zone 2 or Both are the possible settings If you do not intend to use...

Page 4: ...ea page or BOTH for all page Zone 1 karaoke ZR 1 Remote Set PROGRAM SELECT to L1 Adjust LEVEL as needed Set both front panel Zone RMT switches in to enable the Zone Remotes When a priority program juk...

Page 5: ...t control of Zone level and Page level Set the Program PRIORITY ASSIGN switch to Zone 2 This sends pre recorded advertisements or break bell tones to the retail space or shop floor respectively You ma...

Page 6: ...mmended with Program audio inputs driven from long cable lines This is also true for audio sources fed from satellite systems like DSS DMX Primestar AEI TV Cable etc Cable systems are generally earth...

Page 7: ...HANNEL AMPLIFIER OFFICES SALES CREDIT ZR1 MA 3 RIGHT SALES FLOOR DISTRIBUTED ZR1 8 Ohm 70V 8 Ohm PROMO VCR LEFT PRIORITY 2 SERVICE RECEPTION PR2 TUNER OPTIONAL SOURCES PRIORITY 3 PRIORITY 4 HOLE PLUG...

Page 8: ...of the Page Inputs as a Priority Page Input The Priority Pager overrides the non priority Pager in the Zone s it is assigned It is important to note that the non priority Pager may still broadcast in...

Page 9: ...nal hot and the shield gnd wire to ground When unbalanced wiring is used it is very important for the CP 64 and any other unit in the system to have good earth or technical grounds If a unit is locate...

Page 10: ...e front panel of the remote assembly Install any Decora plate of your choice For a secured installation you may wish to leave the knobs off and use a blank Decora plate to cover the remote after adjus...

Page 11: ...ts Page settings repeat for second page input Input Pad Mic Line as required Input gain trim Center 12 00 Detector Threshold Min ccw Active Paging assign Both Paging Level Zone 1 Min Paging Level Zone...

Page 12: ...Detect Threshold rear panel so the Active indicator front panel lights only when you speak If the Page Detect Threshold is set too low the Pager may gate on due to background sound Repeat for second M...

Reviews: