background image

Manual-

RECOMMENDED CALIBRATION PROCEDURE

The CP 64S is a very versatile instrument. While this allows it to conform to the requirements of a large number of system applica-

tions, it also results in complexity. For this reason, it is very important to use an organized approach to system calibration. Once the 

internal switches are set and the system is connected, take the time for proper calibration. The following is an ordered list of system 

adjustments that should make calibration easy and result in optimum performance. Most important:

•   Program Priority Assign 

rear panel

 

off

•   Limiters 

 

rear panel

 

+20 dBu

•   Duckers 

 

front panel

 

OFF

•   Page Zone Levels 

front panel

 

Min

•   Remote Controls 

front panel

 

not

 selected

•   Paging Zone Assigns 

front panel

 

1&2 (both)

RMT

1&2

RMT

1&2

1 2

1 2

ZONE 1

ZONE 2

PAGING

ZONE ASSIGN

LEVEL

L1

P

L2 L3

4k

630

1.6k

40

100

250

10k

CP 64S

ACTIVE

ACTIVE

PAGE 2

PAGE 1

LINE 1

LINE 2

LINE 3

PRIORITY

ON

OFF

SIG

RMT

OL

DUCKER

DEPTH

PROGRAM

SELECT

LEVEL

L1

P

L2 L3

ON

OFF

SIG

RMT

OL

DUCKER

DEPTH

PROGRAM

SELECT

LEVEL

PROGRAM INPUT LEVELS

ZONE 1

ZONE 2

ZONE 2

4k

630

1.6k

40

100

250

10k

ZONE 1

POWER

COMMERCIAL

PROCESSOR

12

6

6

12

0

+

10

0

6

4

2

8

10

0

6

4

2

8

10

0

6

4

2

8

10

0

6

4

2

8

10

0

6

4

2

8

10

0

6

4

2

8

10

0

6

4

2

8

10

0

6

4

2

8

PRIORITY

ASSIGN

ZONE

ZONE

1

PAGE

+30

+60

1&2

PRIORITY

3

2

1

RANE CORP. MADE IN U.S.A.

OL

Z2 Z1

Z1 Z2

+

+

+

+

D1 D0

Vr Vc

Vr Vc

1

2

DETECT THRESHOLD

REMOTE PAGE

ZONE ASSIGN WIRING

PAGE 2

PAGE 1

LIMITER

WIRING

ZONE 1

ZONE 2

PAGE 1

TRIM

PAGE 2

TRIM

CP 64S

+8

+8

PAGING INPUTS

R

L

R

L

+30

+60

MIC

LINE

–20

+20

–20

+20

REMOTES

OUTPUTS

MIN

MAX

PROGRAM INPUTS

ZONE 2

EXPAND OUT

ZONE 1

EXPAND OUT

ZONE

2

Z2 PGM

Z2 EXPAND Z2 MONO

REMOTE 1

INPUT 1

REMOTE 2

INPUT 2

Z1 RIGHT

Z1 EXPAND

Z1 LEFT

Z2 LEVEL

Z1 PGM

Z1 LEVEL

ACN 001 345 482

MIC

LINE

100-240 V

50/60 Hz 12 WATTS

COMMERCIAL AUDIO

EQUIPMENT 24TJ

R

PGM

PGM

PAGE

THIS DEVICE COMPLIES WITH 

PART 15 OF THE FCC RULES FOR 

A CLASS 'B' COMPUTING DEVICE.

 off

Make sure the power is disconnected!

Control Presets:

Page settings (repeat for second page input):

•   Input Pad 

 

rear panel

 

MIC or LINE as required

•   Input gain trim  

rear panel

 

Center (12:00)

•   Detect Threshold 

rear panel

 

Min (CCW, active)

•   Paging Zone Assign 

front panel

 

1&2 (both)

•   Paging Level, Zone 1 

front panel

 

Min

•   Paging Level, Zone 2 

front panel

 

Min

•   Phantom Power 

internal

   

As required. Default Off

•   Pre/Post summing 

internal

   

As required. Default Pre-VCA

•   Page Priority   

internal

   

As required. Default Page 1

Program Input settings:

•   Priority Assign Zone 

rear panel

 

off

•   Program Input Levels 

front panel

 

Min

•   Priority Threshold 

internal

   

Set to -50 at factory (internal adjust -∞ to -35 dBu)

•   Priority Release Time 

internal   

Set to 12 sec. at factory (internal adjust 2 to 20 sec.)

Zone Settings (repeat for second zone):

•   Expand Out   

rear panel

 

As required (Zone/Program/Page)

•   Limiter Threshold 

rear panel

 

CW, +20 dBu

•   Zone Level 

 

front panel

 

Max

•   Program Select  

front panel

 

L1

 (if your input is on L1).

•   Ducker 

 

front panel

 

OFF

•   Ducker Depth   

front panel

 

Center (about 15 dB)

•   RMT (Remote) 

front panel

 

Out

•   EQ   

 

front panel

 

Flat (center detent position)

•   Stereo / Mono switch 

internal

   

As required (Zone 1 only, 

default:stereo

)

System Connections:

•   Connect page mics or line-level paging source

•   Connect Program sources

•   Connect Outputs to amplifiers

•   Connect Remotes

You are now ready to calibrate the CP 64S…

Summary of Contents for CP 64S

Page 1: ...L1 P L2 L3 4k 630 1 6k 40 100 250 10k CP 64S ACTIVE ACTIVE PAGE 2 PAGE 1 LINE 1 LINE 2 LINE 3 PRIORITY ON OFF SIG RMT OL DUCKER DEPTH PROGRAM SELECT LEVEL L1 P L2 L3 ON OFF SIG RMT OL DUCKER DEPTH PR...

Page 2: ...rols are inactive when RMT is selected Two optional wired ZR 1 remotes may be connected to the Remotes port An object smaller in diameter than the switch button is required to engage the RMT switches...

Page 3: ...ne Zone 1 is stereo Zone 2 is mono and both Expand outputs are mono When operating cross coupled line drivers unbalanced it is essential to ground the pin See CP 64S Connections on page Manual 3 7 ZON...

Page 4: ...2 Phantom Power is available for both Page Inputs If phantom power is required for the intended microphone then set the appropriate switch to ON If a Paging Input Mic Line pad switch is set to LINE Ph...

Page 5: ...ble connect the wire to signal hot and both the and shield wires to ground important If you use single conductor cable with shield connect the shield gnd wire to both the and shield pins at the CP 64S...

Page 6: ...Z1 OFF Z2 Z1 Z2 PROGRAM SELECT LEVEL 8 2 10 0 4 6 L1 L3 L2 P Decora plate not included Decora plate not included ZR 1 Zone Volume PR 2 Paging Assign Volume 1 2 3 4 5 S2A 6 7 8 9 10 S2B 2 3 4 1 5 J1A 5...

Page 7: ...20 20 20 20 REMOTES OUTPUTS MIN MAX PROGRAM INPUTS ZONE 2 EXPAND OUT ZONE 1 EXPAND OUT ZONE 2 Z2 PGM Z2 EXPAND Z2 MONO REMOTE 1 INPUT 1 REMOTE 2 INPUT 2 Z1 RIGHT Z1 EXPAND Z1 LEFT Z2 LEVEL Z1 PGM Z1 L...

Page 8: ...etect Threshold rear panel so the Active indicator front panel lights only when you speak If the Page Detect Threshold is set too low the Pager may gate on due to background sound Repeat for second Mi...

Reviews: