FRONT PANEL DESCRIPTION

 BYPASS

 (red) lights whenever the audio relay Bypass for the Channel is active. This occurs for a few seconds after power-

up, or when BYPASS is selected in

 RaneWare

.

 SIGNAL

 (green) indicates the presence of a significant analog audio signal on the Input to the Channel (typically -27 dBu).

 CLIP

 (red) flashes when an audio level for the Channel in the unit approaches digital clipping level (typically 3 dB below

clipping).

 COM

 (yellow, communications) flashes when a message for the unit is received from a PC compatible computer. There is a

brief flash when using the Memory Recall Port.

 POWER 

indicates that the unit is happily connected to a powered remote supply.

RPE 228d CONNECTION

When first connecting the RPE 228d to other components

in your system, 

leave the power supply for last

. This will give

you a chance to correct any mistakes before any damage is
done to your speakers, ears, etc.

The RPE 228d requires a Rane RS 1 (provided with each

unit) or compatible power supply. There are #6-32 screws
provided for chassis ground. Connect a wire from this point to
a known earth ground, such as an amplifier chassis. This may
not be necessary when installed in a rack with other grounded
units.

The RPE 228d will operate at moderately high ambient

temperatures. Large racks of equipment may generate excess
heat, requiring extra space beween units, and/or forced air
ventilation to reduce the ambient temperature in the rack.

The RPE 228d has balanced Inputs and Outputs, with

chassis-grounded shields. This chassis ground is not signal
ground, although the two grounds are connected internally.
The chassis ground is intended to be connected to an earth
ground. The RPE 228d is intended to be connected to other

balanced equipment with chassis-grounded shields. Connect
the non-inverting audio lines to the ‘

+

’ terminals, and the

inverting lines to the ‘

’ terminals. Connect the cable shields

to the ground terminal on the Euroblock or screws. 

Connect

shields at both ends of the cables

.

To control the units from a computer, use nine-pin RS-232

cables which are 50 feet or shorter. 

The cable must 

not

 be a

null-modem type.

 A short cable is supplied for connecting

adjacent units. Daisy-chain up to 16 units at a time by
connecting the COM port on the computer to the INPUT
connector on the first unit, and the OUTPUT connector of
each unit to the next unit’s INPUT.

The DEVICE ADDRESS switch identifies each unit with

an ‘address’, and must be set uniquely for each unit. The
switches form a binary code from 0 through 255. Only the
numbers 1-250 may be used. The place values of each switch
are marked on the rear panel. To set a specific address, refer
to the “Setting the Device Address” section.

Summary of Contents for RPE 228D

Page 1: ...the red telephone style jack on the rear of the unit CAUTION don t connect anything but an approved RANE power supply to this jack If the RS 1 and the RPE 228d are getting power the front panel yello...

Page 2: ...ately high ambient temperatures Large racks of equipment may generate excess heat requiring extra space beween units and or forced air ventilation to reduce the ambient temperature in the rack The RPE...

Page 3: ...ORY RECALL PORT MRP provides contact closure control to recall any of the 16 system Memories for both audio channels Eight of the Memories are recalled with simple switch closure to a single terminal...

Page 4: ...01011101 94 01011110 95 01011111 96 01100000 97 01100001 98 01100010 99 01100011 100 01100100 101 01100101 102 01100110 103 01100111 104 01101000 105 01101001 106 01101010 107 01101011 108 01101100 1...

Page 5: ...ressed files Starting RaneWare A RaneWare folder is now created containing RaneWare the RaneWare Address Calculator and RaneWare Help When the software is first installed RaneWare Help appears Here an...

Page 6: ...ey It s that easy Go ahead and store different curves in different Memories After storing a few clicking any Memory number instantly recalls that Memory Store your favorites in Memories 1 through 8 si...

Page 7: ...Change Password The default password is please With the device locked when a user tries to change a curve this friendly screen appears System Site Control Panel Setup Presets can be customized with n...

Page 8: ...be null modem The cable must be connected to the RW 232 INPUT jack on the rear of the unit Bypass can t be turned off The unit is probably waiting for the computer to download firmware Removing and r...

Reviews: