RANEWARE MENUS

There are three RaneWare pull-down Menus.

The 

System

 menu for “system-level” controls that apply to

the computer or all connected RW 232 devices. The 

Device

menu for device-specific control and the 

Help

 menu for on-

line help.

SYSTEM MENU

These menu commands apply to all connected RW 232

devices and contain the following menu items:

System|System Setup

 displays this screen:

The 

Serial Port

 radio buttons on the left tell the computer

which Com port is being used to “speak” to the connected
RW 232 unit(s). The 

Offline

 radio button permits use of the

software without connecting a unit. To operate an RW 232
unit, you must select the Com (serial) port that is physically
connected to the unit. This screen is also displayed the first
time you start RaneWare or after erasing the RW232.INI file
from your Windows directory.

Most laptop computers have a built in mouse. If you use

an external mouse with your laptop, you may need to use the
built in mouse if your laptop does not have two serial ports—
one for the mouse and a second for the RW 232 unit.

Check the 

Show Memory Names

 check box to display the

Memory names in the RaneWare Button Bar whenever the
mouse is on top of a Memory recall button. Memory names
are edited in the 

Site Control Panel Setup

 window. (See 

Site

Control Panel Setup

 below.)

The 

Remote to RPD 1

 check box is only used with

Rane’s RPD 1 product. Check this box only if you are using
an RPD 1 to remotely communicate with an RW 232 system.
When this box is checked, no communication with local RW
232 devices is possible.
 See 

Dial

 and 

Hang up

 below for more

RPD 1 details.

System|Dial

 and 

System|Hang up

These selections are only used with Rane’s RPD 1

product. The RPD 1 is a telephone interface which, when
used with an external modem, allows remote diagnostics of
RW 232, AMX or Crestron systems. Thus, from the office, a
system designer can call a properly equipped remote system
to view and control that system’s RW 232 settings.

System|Change Password

 displays this screen:

This window allows you to change the password. The

default password set by the factory at the time the software
ships is please. Passwords are case insensitive, therefore,
PlEASe, pLEasE, PLEASE and please are all equivalent. Type
the old password in the Old Password edit box, then type the
new one in the New Password box. Click OK. Then be sure to
note the new password somewhere, preventing future embar-
rassment.

Certain commands such as 

Lock Device

 (see page

Manual-9) or exiting from the 

Site Control Panel 

require the

correct password before they will execute.

Important Note: The computer stores the password, not

the units. Therefore, it is wise to think of the RW 232 pass-
word as the computer’s password, not as each individual
system’s password. This makes it easier to remember the
password since it will be the same for every installation where
you remove the computer once the system is set up. This also
provides the flexibility to have unique passwords for those
installations where a dedicated computer is left on site to
operate the system. If you return to an installation with locked
devices, and do not have the same computer used to initially
lock the devices, you will only need to know the computer’s
password, not the original password used to lock the devices.

System|Edit Installation Info

This selection allows you to enter the 

Project

 name,

installation 

Site

 and 

System Engineer

 for a given project. All

of these are printed on the Device Report printouts. Click in
the edit box or hold the Alt key and press the underlined
character to type new names.

Similar to the password, the 

Site Installation Info

 is stored

in the computer, not in each unit. The 

Site Installation Info

 is

also stored with backup memories when you save a unit’s
memories to a file.

Summary of Contents for RPM 26

Page 1: ...ue address for each unit Apply power by connecting the RS 3 remote supply s 5 pin DIN jack to the rear of the unit then connect the IEC end to a powered AC outlet CAUTION Do not connect anything but a...

Page 2: ...e cable shields to the center terminal on the Euroblock For those installations where the RPM s internal shield to chassis connection causes interference connect the shields directly to the chassis PE...

Page 3: ...ve paint C Now the unit is ready for AC power To power the RPM 26 up and down it is wiser to cycle the AC power cord rather than to unplug and plug the DIN jack 3 DEFAULT switch recalls Memory 1 This...

Page 4: ...l current settings are saved and automatically recalled upon power up unless an RSI contact switch has changed positions while the power was off then it recalls the selected RSI memory The Windows scr...

Page 5: ...K Each unit s Device Address will be displayed within brackets 1 to the left of the device name Double clicking on the device name is equivalent to selecting the device and clicking OK THE RANEWARE SC...

Page 6: ...iagnostics of RW 232 AMX or Crestron systems Thus from the office a system designer can call a properly equipped remote system to view and control that system s RW 232 settings System Change Password...

Page 7: ...anual for detailed instructions Important Note The names you assign become the memory names associated with each RW 232 device on line regardless of the type of device RPM 26 RPE 228 ECS Teleconferenc...

Page 8: ...OK or just double click on the device The Device Edit window for the device you ve selected appears allowing complete control of the device Device Choose DSP Program Choosing DSP Programs is covered...

Page 9: ...ings from a stored file instead of a connected unit This allows you to setup a system save the system s settings to a file and print them at your office saving you the hassle of dragging your printer...

Page 10: ...Help About is very important if you ever need RPM 26 or RaneWare technical support from Rane RPM 26 BASICS The RPM 26 has 2 inputs named Input A and Input B and 6 outputs named Output 1 through Outpu...

Page 11: ...on A few lines describing each DSP Program are listed Generally these descriptions duplicate information available in the simple graphic but some DSP Programs provide much greater functionality than t...

Page 12: ...r on the right shows the A D level in dB Full Scale and indirectly shows the number of bits being toggled by the input signal after passing through the input level control Clicking the Mute button als...

Page 13: ...te as reliable as possible The A D and D A blocks on the RPM 26 Device Edit screen indicate where in the signal chain the A D and D A conversions occur These blocks also contain the signal present and...

Page 14: ...t or view The Freq Hz edit box is changed with the up or down arrows Or click in the edit box to display the cursor and type a new frequency value always in integer Hertz The Level dB edit box is also...

Page 15: ...qualization can use the High Shelf PEQ Filter Type in combination with other PEQ filters to achieve the appropriate EQ for the combina tion of horn and compresssion driver you are using For optimum fr...

Page 16: ...ompressor threshold has been reached All other Compressor settings are adjusted in the Compressor detail window shown at the bottom of this page Double clicking on the Compressor block opens the detai...

Page 17: ...ssover blocks are found in various DSP Programs in the RPM Up to a mono 6 way crossover can be implemented with the RPM s powerful Extended Parametric EQ see the EX TENDED PARAMETRIC PEQ section on pa...

Page 18: ...fiers and speakers This avoids the potential catastrophe of slipping with the mouse or reaching again for your latt and accidentally clicking the mouse SUMMING AND I O ROUTING Some DSP Programs provid...

Page 19: ...the various filter sections in the RPM 26 The graph in the example above does not show the contribution of the crossover since the Crossover box is unchecked LIMITER For most DSP Programs each output...

Page 20: ...st signals The Pink Noise is provided as a test signal for listening to comb filtering in speaker arrays or for listening for room reflections The Sine wave provides a convenient test signal helpful i...

Page 21: ...he RW 232 INPUT jack on the rear of the unit Be sure the Remote to RPD 1 box is not checked in the System System Setup menu This box is only used with the Rane RPD 1 to remotely communicate with an RW...

Page 22: ...01100001 98 01100010 99 01100011 100 01100100 101 01100101 102 01100110 103 01100111 104 01101000 105 01101001 106 01101010 107 01101011 108 01101100 109 01101101 110 01101110 111 01101111 112 0111000...

Reviews: