background image

Manual-21

In addition to the individual signal processing blocks

described above, the RPM 26i contains 

Input

 Blocks and

Output

 Blocks, shown above. These terms simply describe a

subset of the available processing blocks and allow conve-
nient copying of settings from multiple processing blocks.
For example, once you’ve properly set up one-half of a stereo
3-way speaker stack, right mouse click on any output process-
ing block that you’ve already tweaked. A menu appears that
permits clipboard copying of all of the 

Output

 Blocks’

settings (

Copy Output Settings

). This includes the settings

for the Fine Delay, PEQ, Trim and Limiter. Then right click
on the corresponding 

Output

 Block for the other speaker

stack. The pop up menu appears again allowing you to paste
(

Paste Output Settings

) all the settings from the previously

tweaked Delay, PEQ, Trim and Limiter. Then do the same for
the other two loudspeaker drivers and you have a great
starting point to properly adjust the other speaker stack. The

Input

 Block provides this same 

Cut

 and 

Paste

 functionality.

OUTPUT BLOCKS

INPUT BLOCKS &

GENERATOR (PINK NOISE OR SINE)

Pink

 Noise or 

Sine

 wave signals are

available in some DSP Programs. A ‘

G

appears in the simple graphic in the 

Choose

DSP Program

 window, indicating that a

given DSP Program supports these Generator
test signals. The 

Pink

 Noise is provided as a

test signal for listening to comb filtering in speaker arrays or
for listening for room reflections. The 

Sine

 wave provides a

convenient test signal, helpful in setting gain structures or for
more accurately hearing specific-frequency room reflections.

The signal Generators default to a 

Mute

d state when new

DSP Programs containing Generators are requested. Click

Mute

 to unmute the Generator. Click the up or down arrows

to adjust the Generator’s 

Level

 in ½ dB steps. The maximum

attenuation is 40 dB. The Generator levels are calibrated in
dBFS, i.e. at 0dB the Generator is sending a full scale digital
signal to the D/As.

Double-click on the Generator block to open the detail

window. A vertical scroll bar adjusts the Level in three ways.
Click and drag the Thumb directly, click between the Thumb
and the arrows for 5 dB steps or click on the up or down
arrows for ½ dB steps.

Radio buttons on the left allow selection of 

Pink Noise

 or

Sine Wave

 as the Generator source. If 

Sine Wave

 is selected,

the edit box to the right dictates the 

Sine Wave

 frequency in

Hertz. One Hertz steps are accepted.

DSP Programs with two Generators contain 

two

uncorrelated pink noise sources,

 required when you wish to

listen to “stereo” pink noise signals. Also, the two sine wave
generators are 

not

 guaranteed to be in phase. Be sure to

always 

Mute

 the RPM 26i Generators any time you use an

analyzer for system measurements, since the analyzer must
use its own internal generator for such measurements.

MUTE ALL

The 

Mute All

 button is provided for

those moments when you quickly need
to turn all of the RPM 26i Outputs off.

Please note that once all outputs are muted, clicking 

Mute All

again does not unmute all of the outputs.

 All outputs are also

muted each time you choose a new DSP Program from the

Device

 menu’s 

Choose DSP Program

 option. This pur-

posely 

forces the user to unmute each output separately

 and

allows one to reflect on the consequences of unmuting each
output independently.

Summary of Contents for RPM 26i

Page 1: ...AUTION Do not connect anything but an approved Rane power supply to this jack The unit does ground the chassis through the power cord If the RS 3 and the RPM 26i are getting power the yellow front panel POWER indicator will be on Start your computer run Windows and launch RaneWare by double clicking on the RaneWare umbrella icon See the next page for software installation instructions The Help fil...

Page 2: ...shers that the cable screws into Be sure to screw down RS 232 cables to guarantee good shield connections The chassis and the audio signal ground are connected together internally at only one point The RPM 26i chassis connects through the RS 3 power supply cables to the earth ground 3rd pin of the 100 and 120 VAC line cords A 6 32 screw and star washer are also provided on the unit s rear if a tec...

Page 3: ...n the appropriate DSP Programs for your system This avoids the problem of accidentally recalling a Memory which could be detrimental to the system On the other hand this feature is useful in rental systems for example where fixed DSP Programs can be stored in various Memo ries requiring only an MRP wiring alteration to change the signal processing from a 2 way to a 3 way system 햶 RW 232 OUTPUT con...

Page 4: ...r crashes the unit continues to operate and keeps its current settings If the unit loses power all current settings are saved and automatically recalled upon power up unless an MRP contact switch is on then it recalls the selected MRP Memory See Memory Recall Port on page Manual 23 The Windows screens perform the traditional function of a front panel displaying and editing the device s settings Fo...

Page 5: ...wn below is called the Device Edit screen The RaneWare screen also contains a Button Bar and typical Windows pull down Menus The RaneWare screen gives you complete control of all signal processing functions as well as access to all system level controls such as COM port selection and the Site Control Panel that recalls Memories stored in multiple RW 232 devices The system picture in each Device Ed...

Page 6: ...ond for the RW 232 unit Check the Show Memory Names check box to display the Memory names in the RaneWare Button Bar whenever the mouse is on top of a Memory recall button Memory names are edited in the Site Control Panel Setup window See Site Control Panel Setup below The Remote to RPD 1 check box is only used with Rane s RPD 1 product Check this box only if you are using an RPD 1 to remotely com...

Page 7: ... Note The names you assign become the Memory names associated with each RW 232 device on line regardless of the type of device RPM 26i RPE 228 ECS Teleconferencing system etc If you set up the button corresponding to Memory number 1 to represent a particular sound system configuration make sure Memory number 1 in each device in the system is pre programmed appropriately for this particular sound s...

Page 8: ...s return or click OK Note You do not have to type an extension to the filename unless you want to The program automatically appends RPM as the file extension Also the current project name site and system engineer information entered through the Edit Installation Info dialog box is automatically saved in each RPM file Backing up device Memories is highly recommended Just like any computer data the ...

Page 9: ...ice Lock Device Lock Device allows you to lock a device to prevent unauthorized users from making changes to your pro grammed settings in the device s Memories Although a device is locked different presets can still be recalled by selecting another Memory via the Site Control Panel the Memory Recall Port or by clicking on a desired Memory key on the button bar with the mouse The data previously st...

Page 10: ...ve window appears You can select one or more Memories to print To select a single Memory to print click on your choice then click OK As with many Windows selection boxes to select a contigu ous range of Memories click on the first Memory choice then hold down the Shift key and click on the last Memory choice of the range This is a handy way to print Memories 1 through 5 for example or even all 16 ...

Page 11: ...to Filter 1 s new values Filter 2 s settings do the same et cetera Ramping is disabled via the Ramp Disable checkbox at the bottom of the Device Edit screen It is wise to keep like numbered filters in a similar frequency range when changing Memories For example always set filter number one as your lowest frequency PEQ filter This way when changing Memories where filters move the ramping algorithm ...

Page 12: ...d DSP Program the Inputs and Crossovers check boxes near the top of the screen allow the user to reduce the DSP Program list to include only those Programs matching the checked criteria For example if one desires only two input 3 way crossovers de select all but the Two Input and 3 Way check boxes The displayed list is then reduced to only two DSP Programs both Programs 4 and 5 provide a Dual 3 wa...

Page 13: ...ng entire Input or Output block settings If you find yourself squeezed for room at the bottom of the screen you can modify the Task Bar so it only appears when you move the mouse pointer below the bottom of the screen To do this Right Click on a blank spot on the task bar Select Properties Enable Auto Hide Click OK While operating the Site Control Panel in Windows there is no button box for the sy...

Page 14: ...our pal the Windows operating system Displaying meters on computers poses a unique problem for software designers and sometimes for users especially if you have a slow computer Everyone is familiar with analog meters without computers deciding that display ing meter indicators needs to wait until a more important task is completed Windows provides the RPM 26i software an update window opportunity ...

Page 15: ... select a different filter s settings You may also click directly on the circled number on the graph corresponding to the filter to edit or view it The Freq Hz edit box is changed with the up or down arrows Or click in the edit box to display the cursor and type a new frequency value always in integer Hertz The Level dB edit box is also changed with its up or down arrows Or click in the edit box t...

Page 16: ...in three ways Clicking the left or right arrows adjusts the bandwidth one step at a time Clicking between the arrows and the sliding box thumb adjusts the bandwidth 10 steps at a time Clicking and holding the thumb allows dragging the control A Bypass check box appears on the bottom right allowing the selected PEQ filter to be bypassed This is essentially equivalent to setting that filter s level ...

Page 17: ...f You must click directly on the curve to the left of the Threshold point or knee to alter the Threshold The vertical position of the cursor corresponds to the Threshold level once the curve is successfully grabbed Click directly on the curve to the right of the knee to alter the Ratio setting The curve changes color when successfully grabbed DELAY All DSP Programs provide two types of Delay block...

Page 18: ...ous DSP Programs in the RPM Up to a mono 6 way crossover can be implemented with the RPM 26i s powerful Extended Parametric EQ see the Extended Parametric PEQ section on pages Manual 15 16 for details on implementing more than a 3 way crossover The 2 and 3 way crossover interfaces are similar Only the 3 way is covered here The 2 way interface simply removes one band The 3 way crossover block is sh...

Page 19: ...onnected to amplifiers and speakers This avoids the potential catastrophe of slipping with the mouse or reaching again for your latté and accidentally clicking the mouse SUMMING AND I O ROUTING Some DSP Programs provide simple Input Summing that is generally accompanied by I O Routing The circled plus sign between the two Input Blocks indicates that summing is supported A schematic drawing of a th...

Page 20: ... RPM 26i The graph in the example above does not show the contribution of the crossover since the Crossover box is unchecked Right mouse click on the Detailed Response Window to zoom in or out or to print LIMITER For most DSP Programs each output is supplied with a Limiter The limiter is meant to be a safety device to stop the RPM 26i Output from exceeding a predetermined threshold voltage The Lim...

Page 21: ... hearing specific frequency room reflections The signal Generators default to a Muted state when new DSP Programs containing Generators are requested Click Mute to unmute the Generator Click the up or down arrows to adjust the Generator s Level in dB steps The maximum attenuation is 40 dB The Generator levels are calibrated in dBFS i e at 0dB the Generator is sending a full scale digital signal to...

Page 22: ...er up the unit may need erasing This reinitializes all of the stored parameters including names and resets all Memories to DSP Program 3 To erase hold the DEFAULT button while turning the power on Be sure to hold the DEFAULT button until the Output LEDs cycle When the unit is finished erasing the Output LEDs cycle yellow from the outsides to the center If you are unable to stop either the Output 1...

Page 23: ...nges in contact position s are detected either latching or momentary switches may be used However when wiring contacts only use Normal Paging or Binary mode do not switch between modes The MRP may be programmed so that any input code including no connection may recall any Memory 1 2 3 4 5 6 7 8 Mode Result 1 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 2 0 0 1 0 0 0 0 0 3 0 0 0 1 0 0 0 0 4 0 0 0 0 1 0 0 0 5 0 ...

Page 24: ...102 01100110 103 01100111 104 01101000 105 01101001 106 01101010 107 01101011 108 01101100 109 01101101 110 01101110 111 01101111 112 01110000 113 01110001 114 01110010 115 01110011 116 01110100 117 01110101 118 01110110 119 01110111 120 01111000 121 01111001 122 01111010 123 01111011 124 01111100 125 01111101 126 01111110 127 01111111 128 10000000 129 10000001 130 10000010 131 10000011 132 100001...

Reviews: