21
Zones
(Outputs)
General
Level:
This is the output volume level.
Input Source:
This is the audio source of the
zone.
Priority Source:
This is the audio source that
will play automatically when an incoming
signal is detected.
Priority Hold Time:
This determines how long it will take (in seconds) for the output to
switch back to the original audio source after the priority source signal falls below the
threshold.
Low Shelf
Level:
This is the amount of “boost”
(increase) or “cut” (decrease) of the low-
frequency shelving filter.
Frequency:
This is the center frequency of
the low-frequency shelving filter.
Parametric EQ (PEQ)
Level:
This is the amount of “boost”
(increase) or “cut” (decrease) of the mid-
range parametric equalization band.
Frequency:
This is the center frequency of
the mid-range parametric equalization
band.
Bandwidth:
This is the width of the mid-
range parametric equalization band.
High-Shelf
Level:
This is the amount of “boost”
(increase) or “cut” (decrease) of the high-
frequency shelving filter.
Frequency:
This is the center frequency of
the high-frequency shelving filter.
Paging
Enable:
This feature determines whether or
not the zone will receive an audio signal
from the pager.
Level:
This is the output volume level of
the pager.
Ducker Depth:
This determines how much
the pager, when activated, will attenuate
the normal output signal.