WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
28
A
B
C
ArtNo.311-0010 Injectors
A – Jet, B – Internal injector, C – External injector
Check the
‘Technical Data’
section at the back of the book
that the hob is convertible to the gas you want to use.
A suitably competent person must perform the conversion.
After conversion the installation must comply with the
relevant regulations and the local electricity supply company
requirements. Read the instructions before converting this
appliance.
n
n
Failure to convert the appliance correctly could
invalidate any warranty or liability claims and lead
to prosecution.
n
n
When servicing or replacing gas-carrying
components disconnect from the gas supply before
starting operation. Check the appliance is gas sound
after completion.
n
n
DO NOT use reconditioned or unauthorised gas
controls.
n
n
Disconnect from the electrical supply before
servicing. Before electrical reconnection, check the
appliance is electrically safe.
Injectors
Remove the burner caps and heads. Remove the old jets
(Fig.9.1)
. Fit the new jets (see
‘Technical Data’
section at the
back of the book for correct jets). Reassemble in the reverse
order.
Tap Adjustment
Removing the Control Panel
Pull off all the control knobs.
Remove the 3 fixing screws at the rear of the top edge of the
control panel. Remove the 2 screws – one at each end – on
the underside of the control panel. Pull the control panel clear,
taking care not to damage or strain the wiring. Disconnect the
wiring.
Remove the two screws holding the shield in front of the
control taps and remove the shield.
Bypass Screw Adjustment
Turn the bypass screw on each control clockwise to the stop
(Fig.9.2)
.
Refit the control panel.
Stick on Label
Stick the LP gas label over the natural gas part of the
appliance data label.
ArtNo.0102-0011 - Screwing
the control valve bypass screw
9. Conversion to LP Gas
Fig.9.1
Fig.9.2