background image

9

Due to our policy of continual improvement, we reserve the right to change specifications without prior notice.

n

n

When dispensing hot water always be mindful to 

keep your hands and arms from being under the 

spout exit. Even though it is thermally insulated, you 

should avoid touching the very end of the spout, 

especially immediately after dispensing hot water.

n

n

This product has a unique safety system by using the 

HotFob magnetic key to dispense the near boiling 

water. If you want to prevent the accidental use of 

the near boiling water function only, then store the 

HotFob away from the tap. 

n

L

The HotFob is magnetic to allow you to ‘stick’ it in 

out of reach places (such as the fridge or the cooker 

hood). With the HotFob away from the tap, it can 

only be used as a conventional tap without the hot 

water function.

n

L

If the tap can only be used by competent adults, 

then the HotFob can be ‘stuck’ to the rear of the tap 

body (Fig. 5.3) when not in use for more convenient 

access.

Magnetic fields: The ‘HotFob’ key houses a strong 

magnet used to sense its proximity to the 

mixertap and also for convenience when storing 

the HotFob. Any customers with a pacemaker 

should not place the HotFob within 5 inches 

(100mm) of such devices. 

All magnets can damage electronic devices and bank cards so 

they should be stored away from each other.

Fig. 5.3

 

Summary of Contents for GEO

Page 1: ...Instructions for GEO and AGA 4 in 1 tap boiler units BOILER FOR 4 IN 1 TAP Installation Instructions Aftercare Information U110651 02a...

Page 2: ...he water temperature 7 5 Using the Product 8 6 Descaling the Boiler system 10 7 Filter 12 8 Draining the Boiler system 16 9 Troubleshooting maintenance 17 10 Specifications 20 11 Circuit Diagram 22 12...

Page 3: ...ater in the tank has cooled to a safe temperature n n WARNING Do not use this appliance if you suspect it or any of its hoses are damaged in any way or is performing differently from how you would exp...

Page 4: ...device such as a timer or connected to a circuit that is regularly switched on and off by the utility n n Do use any water jet or steam near this appliance n n This appliance should have at least 10m...

Page 5: ...n Filter reminder Power button Scroll arrows Menu button Status information Time Status indicator Preferred temperature Filling The boiler is filling with fresh cold water to replace the hot water jus...

Page 6: ...er No water No water supply self diagnostic error confirm water supply is on if problem persists contact service agent on top of boiler PCB Fault PCB self diagnostic error contact service agent on top...

Page 7: ...backlight brightness between 1 5 3 Once satisfied with the new backlight brightness value hold MENU to store 4 Now the contrast values will flash Repeat for the contrast 5 Hold MENU to store and to e...

Page 8: ...he least energy efficient setting Shutting down 1 To shut down the product the POWER button should be held when on the normal operation screen for 10 seconds 2 The shutdown screen will appear and usin...

Page 9: ...st This will happen faster if some of the stored hot water is dispensed and therefore replaced with cold Note it is normal as with any hot water dispenser that thermal energy is lost by the time it is...

Page 10: ...weeks you should flush 10 litres 3 Hot domestic water This is delivered when the left tap handle is pulled forwards 4 Hot boiled filtered water This is delivered when the HotFob key is moved close to...

Page 11: ...the HotFob away from the tap L L The HotFob is magnetic to allow you to stick it in out of reach places such as the fridge or the cooker hood With the HotFob away from the tap it can only be used as...

Page 12: ...switch off the boiler at the front control panel see user guide powering down for more details 2 Wait until the flexible connector B9 has cooled to a safe touch temperature this may take some time Fig...

Page 13: ...wice repeat the flushing procedure as described in steps 9 to 13 until it subsides n n The boiler descaling agent has been formulated and tested specifically for your appliance no alternative descalin...

Page 14: ...and has an audible beep when it reaches its estimated end point This is based on average volume and time limits and is designed to help remind you to check the filter Each installation has a differen...

Page 15: ...e REPLACE LITRES value in the table for 13 Clark is 850 litres In this example the WATER USAGE is more than REPLACE LITRES so the filter requires replacement Replacement filters can be obtained by con...

Page 16: ...leared cold filtered water will come from the tap The water might at first be discoloured but this is normal and will clear with flushing 10 With a kitchen measuring jug and a clock you must A Flush a...

Page 17: ...en rinse with warm water and then dry off the tap again to prevent water marks reappearing as the water evaporates Where the tap has a removable aerator on the spout exit it can be removed and cleaned...

Page 18: ...protective wear to prevent accidental scalding from hot water surfaces and steam 1 Use the HotFob to drain hot water from the tank until no more water can be dispensed 2 Ensure the boiler A1 is turned...

Page 19: ...e turn off appliance at plug See silver front plate for service contact details The water supply to the boiler is turned off The water pressure is low The inlet filter is blocked with debris Electrica...

Page 20: ...nearer balance the pressures Domestic hot water temperature is too low Increase the boiler output temperature to help compensate Water is spraying from the spout end Aerator is blocked or partially bl...

Page 21: ...asks any such naturally occurring tastes in the water Flush the tap for longer before use if the taste persists it is most likely as described Water is cloudy Air in the water You can check for air in...

Page 22: ...at 3 bar Varies by model refer to tap specifications Note inlet flow limiters are available separately to flow limit the tap if required to meet varying building standards For further detailed inform...

Page 23: ...bar Maximum cold water pressure 8 bar Filter mesh rating 5 micron nominal rating Primary filter contents Activated carbon block Ion selective media Capacity activated carbon 1700 litres approximately...

Page 24: ...m Key QTY Description A1 1 Boiler unit A2 1 1 5m Power lead A3 1 Boiler mounting bracket A4 1 Boiler bracket to base unit screw A5 2 Boiler bracket screw A6 1 Data connection lead A7 1 Safety steam ov...

Page 25: ...tube type C3 1 Filter head including check valve C4 1 Flush Drain pipe C5 1 Filter cartridge C6 2 Filter head screws C7 1 3 8 stem x push fit C8 1 x 1500mm Tube thinner tube type C9 1 x x Push fit eq...

Page 26: ...dvisory Service All materials WRAS compliant with the exception of the pump which complies to NSF Part G building regulations Hot water safety All safety and discharge devices supplied as standard wit...

Page 27: ...ur statutory rights 5 No warranty applies to the filter cartridge life this is effected by the setup varying water quality and personal pattern of usage and as such the combination of these variables...

Page 28: ...26 Notes...

Page 29: ...27 Notes...

Page 30: ...28 Notes...

Page 31: ...29 Notes...

Page 32: ...Clarence Street Royal Leamington Spa Warwickshire CV31 2AD England Tel 44 0344 5765597 GEO Email consumer agarangemaster co uk AGA Email customerrelations agarangemaster co uk...

Reviews: