27
10. Technical Data
The cooker is category II2H3+
It is supplied set for group H natural gas. A conversion kit from NG to LP is packed with the cooker.
INSTALLER:
Please leave these instructions with the User.
DATA BADGE LOCATION:
Cooker back, serial number repeater badge below oven door opening.
Connections
Gas
(Rp ½ at rear right-hand side)
Electric
Natural gas
20mbar
220-240V 50Hz
Butane
29mbar
Propane
37mbar
(See the appliance badge for test pressures)
Dimensions
Overall height
minimum 898mm
maximum 925mm
Overall width
900mm
Overall depth
650mm
Refer to 'Positioning the Cooker'.
Ratings
Natural Gas 20mb
L.P. Gas
Hotplate
Injector
Screw
Injector
Screw
Wok burner
3.5kW
internal 80
96
3.5kW (246g/h)
internal 54
57
external 129
external 77
Large burner
3.0kW
134
54
3.0kW (210g/h)
87
40
Medium burner
1.7kW
109
39
1.7kW 119g/h)
68
32
Small burner
1.0kW
75
38
1.0kW (70g/h)
51
28
Oven Efficiency
Ovens
Main oven
Tall oven
Forced air convection
Forced air convection
Maximum output
2.5kW
2.5kW
Energy efficiency class on a scale
of A (more efficient) to G (less efficient)
A
B
Energy consumption based on standard load
0.85kWh
0.95kWh
Usable volume (litres)
67
53
Size
Large
Medium
Time to cook standard load
38 minutes
49 minutes
Surface area of the grid
1400cm
2
790cm
2
Grill
2.3kW
Maximum total electrical load at 230V
7.4kW (approximate total including oven lights, oven fan, etc.)
ArtNo.105-0008 - Technical data - 90 induction - Elan
Summary of Contents for Professional+
Page 30: ...28 ...
Page 31: ...29 ...
Page 32: ... www rangemaster co uk ArtNo 000 0003 CE logo DocNo 000 0001 Back cover Rangemaster ...