12
CARE AND CLEANING OF YOUR BEVERAGE CENTRE
Condenser
The condenser underneath the cabinet does not require
frequent cleaning; however, satisfactory cooling depends on
adequate ventilation over this heat exchanger. It is recom-
mended to annually clean the condenser by vacuuming and
brushing. To access the condenser, the unit must be pulled
out from the installation, and the lower machine compart-
ment access cover removed.
Disconnect the power cord before removing the access
cover.
Be sure that nothing obstructs the required air flow openings
in front of the cabinet. At least once or twice a year, brush
or vacuum lint and dirt from the front grille area
(see page 3).
Cabinet
The painted cabinet can be washed with mild soap and
water and thoroughly rinsed with clear water. NEVER use
abrasive scouring cleaners.
Interior
Wash interior compartment with mild soap and water. Do
NOT use an abrasive cleaner, solvent, polish cleaner, or
undiluted detergent.
Pull-out Racks
The racks may be cleaned with mild soap and water and a
soft cloth. Do NOT use any abrasive cleaners.
Glass Door
Use a glass cleaner or mild soap and water and soft cloth
to clean the glass door model. Do NOT use any abrasive
cleaners.
Door Gasket
The vinyl gasket may be cleaned with mild soap and water,
a bicarbonate of soda solution, or a mild scouring powder.
Light Bulb Replacement
DISCONNECT THE POWER CORD BEFORE ATTEMPTING
LIGHT BULB REPLACEMENT. Failure to do so may result in
an electrical shock that could severely injure you.
The RBC38 and RBC60 use one, 25 watt incandescent light
bulb to illuminate the interior of the refrigerator. The light
bulb is a very reliable electrical component, but should it not
function properly, please call the dealer where you pur-
chased your refrigerator from for a replacement light bulb.
Use only an original equipment light bulb from your dealer
or Rangemaster.
Do NOT under any circumstance use a light bulb that ex-
ceeds 25 watts!
To replace the light bulb, disconnect power to the unit. Un-
screw the old light bulb located behind the display housing
at the top of the unit. Set the old light bulb aside. Screw
the new light bulb into place. Reconnect power to the unit.
Check to see if the light bulb operates properly to complete
the installation.
The light bulb is not covered by your warranty. A replace-
ment bulb can be obtained from your dealer or from Range-
master.
In the Event of a Power Failure
If a power failure occurs, try to correct it as soon as possible.
Minimize the number of door openings while the power is
off so as not to adversely affect the unit’s temperature.
If a power interruption occurs, the unit may take 5 to 10
minutes to restart.
NOTE
Summary of Contents for RBC38
Page 19: ...NOTES...