background image

Stage 3 – setting up the filtered water flow rate:  

 
Turn your filter tap on fully so filtered water runs through it. 
Note: when the filter is new it will take a moment to push any 
air though the system, so water may not appear instantly. 
You may notice some black discoloration in the water at this 
point, this is loose carbon, it is normal and harmless and will 
pass with further flushing. We suggest flushing apx. 20 litres 
through the filter when new. 
 
The filtered drinking water system performs at a maximum of 2-
3 L / min depending upon the quality of your water.  
Turn the blue lever on the three way valve (V) to adjust the 
flow of filtered water to the appropriate flow rate, this can be 
checked using a kitchen measuring jug for example 1 litre 
should take 20-30 seconds.

 

 

 

 

 

 
After installation: 

 
Once you have visually checked the installation of the new tap and all connections, ensure that all other fittings 
are closed except the new tap which should be left open.  
 
Turn on your water heating system and ensure that your mains stopcock is open.  
 
Check the function of flow and function of hot, cold, filtered and mixed water. 
 
Turn off the tap and check carefully for any leaks around all connections on the fitting and adjoining plumbing. 
If possible return to the installation after a longer period to double check for slower leaks. If pressure testing 
equipment is available check the installation to the maximum recommended pressure. 
 
Clean the tap to remove any marks created during installation as instructed then place a bag over the product 
to protect the tap until it is ready for use. 
 
The installation should be periodically checked for damage, if the property is left unattended for a prolonged 
period we recommend isolating water supplies. 

 

Using the tap: 

 
Push the right side handle backwards for filtered water, forwards for unfiltered water. 
 
For best results when using the filtered water always run the tap for a few moments to flush away any standing 
water. The longer the filter has been unused the longer the system will need to be flushed. Running the filtered 
tap will also make the water cooler for drinking.  
 
When comparing the taste of filtered and unfiltered water always taste the filtered water first. 
 
The dual stage filter is designed to improve the taste, clarity and odour of drinking water, it will not effect the 
water hardness (limescale) qualities. 
 
Depending upon the quality of the incoming water source the blue lever on isolation valve (U) should be 
adjusted. The worse the quality of the incoming water the slower the flow rate of filtered water should be set in 
comparison with the suggested optimum rate.  
 
Each filter cartridge has a maximum 6 month lifespan. Complete and return the included registration card if 
you wish to take advantage of our free postal reminder card service. 

 

 

 

TSA1 – Traditional Filter Spa Monobloc 

 

PLEASE LEAVE THESE INSTRUCTIONS 

FOR YOUR CUSTOMER.

 

FOR REPLACEMENT PARTS & 

TECHNICAL ADVISE CALL 0870 789 5108

 

5 Year warranty Terms and Conditions: 

 
In the unlikely event that you should experience any defect in the materials or workmanship of your new Leisure mixer within FIVE 
years of purchase, the purchaser’s sole remedy shall be the replacement (at the manufacturer’s discretion) of all or any part of the 
product that is defective. All working parts and valves are guaranteed for a period of TWO years from purchase. Decorative surface 
finishes and O-rings are guaranteed for ONE year from the date of purchase provided that our advice concerning care has been 
observed and no scouring agents have been used.  
This is provided that the mixer has been used for normal domestic purposes in the UK or Eire and that the care, installation and 
maintenance instructions have been observed. The warranty extends to the original purchaser only. You should retain a copy of your 
dated invoice as proof of purchase to validate any claims under this guarantee. 
 
Marks, scuffs and scratches caused by improper installation or accidental damage are not covered by this guarantee. Neither are 
shade variations or any damage or defect caused by incorrect installation or abuse of the fitting.  
As we are continuously improving and developing our range of products, finishes & colours, in the event of a valid claim, we may not be 
able to provide an identical replacement for the defective product throughout the guarantee period. Where an identical product is no 
longer available, we will supply the nearest equivalent from our then current product range. In assessing your claim, we must be given 
the opportunity to inspect the product as installed prior to removal. Any product returns must be packaged as received and complete. 
 
No other warranties, express or implied, are made, including merchantability or fitness for a particular purpose. Under no 
circumstances shall the manufacturer be liable for any loss or damage arising from the purchase, use or inability to use this product, or 
for any special, indirect, incidental or consequential damages. No liability is accepted for consequential damage to other household 
fixtures, fittings or furnishings arising from this claim, even if attached to the product. No installer, dealer, agent or employee of Aga 
Rangemaster Limited has the authority to modify the obligations or limitations of this warranty. 
 

Care Instructions for your Kitchen Sink Mixer: 

 
To maintain the appearance of this tap, ensure that it is regularly cleaned only using a clean, soft damp cloth. 
A solution of warm water and a mild liquid detergent may be used where necessary, and then the fitting rinsed 
thoroughly and wiped dry. Any other cleaning action will invalidate your warranty.  

 

Abrasive cleaners, scouring cleaners and acidic cleaners must not be used under any circumstances. Avoid 
contact with all solvents (including chlorinated solvents, ketones or acetones as these may result in surface 
deterioration or etching). Also avoid contact with any harsh household chemicals such as oven cleaners, drain 
cleaners, rust removers, paint strippers, bar keepers friend or Brasso. 

 

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to 
maintain optimum flow performance. 

 

Important Technical Data: 

 

Min / Max Hot operating pressure: 0.3 / 5.5 bar* 
Min / Max Cold operating pressure: 0.75 / 5.5 bar* 

 

Recommended / Maximum hot water temperature:  46 / 70°C* 

Tap hole size and centres: 

35mm 

 

Flow characteristics: Dual flow

 

 

*If these temperatures or pressures are exceeded, even for short 
periods, damage can result. In these instances a thermostatic mixing or 
pressure reducing valve should be installed. 

 
This product is either WRAS approved or manufactured in accordance with recognised European standards. 
Please ensure that your Kitchen mixer is fitted in accordance with Local Water Byelaws. Where hot and cold 
water mix within the mixertap, then suitable non return (check) valves should be installed to the hot and cold 
supplies to prevent backflow. 

 

Hot and cold supply pressures should be as closely balanced as possible for best results. Supply pipes should 
maintain the maximum diameter until immediately before the fitting. The differential between the hot and cold 
water supply temperatures should be sufficient to allow correct mixing function. 

 

These installation guidelines have been prepared for your direction and you must exercise due care at all 
times. We do not accept responsibility for problems that may occur through improper installation. Whilst 
assembling the tap take care not to accidentally loosen any factory fixed assemblies. 

 

This tap has been 100% assembly tested; therefore you may expect a small residual amount of water to 
remain in the tap when delivered. Any water marks can be removed using the above care advice. 

 

This tap can be used in conjunction with a water softening system and will remove the need for a separate 
drinking water tap. In this instance the isolator valve (U) must cut into the unsoftened cold mains supply. 
 

Reviews: