- 11 -
TR-127GK/DX
CHAPTER 4
ALIGNMENT
4.0 REQUIRED TEST EQUIPMENT
c
DC Power Supply (13.8VDC, 10A)
d
RF Wattmeter (10W)
e
Multi-meter
f
Automatic Modulation Meter
g
Audio Signal Generator
h
Frequency Counter (100 MHz)
i
RF Signal Generator (100 MHz)
j
Automatic Distortion Meter
k
Oscilloscope (50 MHz)
l
Sinad Meter
4.1 ALIGNMENT PROCEDURES
This transceiver has been aligned at the factory and does not require any adjustments at installation.
The required test equipment listed are used for the test setup or alignment shown in Figure 4-1
Transmitter Test Setup and Figure 4-2 Receiver Test Setup. These test setups are used in part or total
during the following adjustments. Refer to page 14 for adjustment locations.
4.1.1 PLL ALIGNMENT
ITEM U.U.T.
SETTING
ADJUST
POINT
MEASUREMENT
VCO
Set radio to CH 1 AM RX mode.
Connect Multi-meter to TP9.
L23
2.5 VDC
±
0.1
Connect Oscilloscope to TP3.
L24
Adjust for max.
AM Frequency Set radio to CH 19 AM RX mode.
Connect Frequency Counter to TP3.
L29
16.4900MHz
±
20Hz
AM OSC
Set radio to CH 19 AM TX mode.
Connect Frequency Counter to TP5.
L23
10.6950MHz
±
10Hz
Summary of Contents for TR-127GK/DX
Page 1: ...REV A Dec 2004 TR 127GK DX 40 CHANNEL AM CB MOBILE RADIO Service Manual Communications Inc ...
Page 14: ... 13 Figure 4 1 Transmitter test setup Figure 4 2 Receiver test setup ...
Page 15: ... 14 TR 127GK DX MAIN PCB ADJUSTMENT LOCATION ...
Page 18: ... 17 TR 127GK DX ROTARY SWITCH PCB EPT092920Z SMD COPPER SIDE COMPONENT SIDE ...
Page 20: ... 19 TR 127GK DX DISPLAY PCB EPT092930Z COMPONENT SIDE COMPONENT SIDE COPPER SIDE ...
Page 22: ... 21 TR 127GK DX MAIN PCB EPT012910A COMPONENTS SIDE ...
Page 23: ... 22 TR 127GK DX MAIN PCB EPT012910A COPPER SIDE ...
Page 26: ...TR 127GK DX SCHEMATIC DIAGRAM ...
Page 29: ...AT0127040A COPYRIGHT 2004 Ranger Communications Inc Communications Inc ...